MétaCan
Menu
Back to cohort
Record W2073188168 · doi:10.1118/1.1376442

Calculation of beta‐ray dose distributions from ophthalmic applicators and comparison with measurements in a model eye

2001· article· en· W2073188168 on OpenAlexaff
W. G. Cross, J.E.I. Hokkanen, H Järvinen, Firas Mourtada, P Sipilä, C. Guedes Soares, S. Vynckier

Bibliographic record

VenueMedical Physics · 2001
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsAtomic Energy (Canada)
Fundersnot available
KeywordsMonte Carlo methodOpticsPlanarNuclear medicinePhysicsBeta particleDosimetryPoint sourceScatteringComputational physicsMaterials scienceMathematicsMedicineStatisticsComputer scienceAtomic physics

Abstract

fetched live from OpenAlex

Dose distributions throughout the eye, from three types of beta-ray ophthalmic applicators, were calculated using the EGS4, ACCEPT 3.0, and other Monte Carlo codes. The applicators were those for which doses were measured in a recent international intercomparison [Med. Phys. 28, 1373 (2001)], planar applicators of 106Ru-106Rh and 90Sr-90Y and a concave 106Ru-106Rh applicator. The main purpose was to compare the results of the various codes with average experimental values. For the planar applicators, calculated and measured doses on the source axis agreed within the experimental errors (<10%) to a depth of 7 mm for 106Ru-106Rh and 5 mm for 90Sr-90Y. At greater distances the measured values are larger than those calculated. For the concave 106Ru-106Rh applicator, there was poor agreement among available calculations and only those calculated by ACCEPT 3.0 agreed with measured values. In the past, attempts have been made to derive such dose distributions simply, by integrating the appropriate point-source dose function over the source. Here, we investigated the accuracy of this procedure for encapsulated sources, by comparing such results with values calculated by Monte Carlo. An attempt was made to allow for the effects of the silver source window but no corrections were made for scattering from the source backing. In these circumstances, at 6 mm depth, the difference in the results of the two calculations was 14%-18% for a planar 106Ru-l06Rh applicator and up to 30% for the concave applicator. It becomes worse at greater depths. These errors are probably caused mainly by differences between the spectrum of beta particles transmitted by the silver window and those transmitted by a thickness of water having the same attenuation properties.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.027
GPT teacher head0.320
Teacher spread0.293 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations51
Published2001
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207