SU‐FF‐T‐389: Sensitivity of Document Scanners Used for Radiochromic Film Dosimetry

2006· article· en· W2073516219 on OpenAlexaff
Y Wang, David F. Lewis, E Poon, Frank Verhaegen, E. B. Podgoršak, Slobodan Dević

Bibliographic record

VenueMedical Physics · 2006
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsMcGill University Health Centre
Fundersnot available
KeywordsScannerDosimetryOpticsSensitivity (control systems)PixelMaterials scienceCalibrationImage resolutionRGB color modelImage qualityPhysicsNuclear medicineComputer scienceArtificial intelligenceImage (mathematics)

Abstract

fetched live from OpenAlex

Purpose: The use of color CCD‐based document scanners, having an ability to perform scans in the transmission mode, has been suggested as an inexpensive option in the process of radiochromic film dosimetry. These scanners allow acquisition of transmission scans in up to a 48‐bit red‐greenblue (RGB) mode. Since the absorption spectrum of the radiochromic film exhibits a maximum in the red region of the visible spectrum, extraction of the red channel from the RGB image improves document scanner sensitivity when used in combination with radiochromic films. However; transmission scanners use a linear CCD array that suffers from a difference in response along the array. In this work, we present our measurements of the spatial response of an AGFA Arcus II document scanner used for radiochromic film dosimetry. Method and Materials: To create various pixel value levels, we employed 5 neutral density filters and their combinations. The profiles were fitted with the sixth order polynomial and consequently used for image correction. The sensitivity curves have been created by normalizing their values to the central profile value. Results: In the regions close to scanner bed edges, the non‐uniformity of the raw pixel data depends on the pixel level detected by the CCD array and can be as large as 15%. Over the 80% of the scanning region, the uniformity is of the order of 2% after corrections are applied. However in areas close to the left and right edges of the scan deviations can reach 5% even after the correction. Conclusions: We have demonstrated that in transmission scanners, using linear CCD array detectors, a considerable change in sensitivity may occur along the detector array direction. If not properly corrected for, this spatial sensitivity may obscure a 2D accuracy of the radiochromic film dosimetry. Conflict of interests: Research is sponsored by ISP.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.275
Teacher spread0.269 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2006
Admission routes1
Has abstractyes

Explore more