MétaCan
Menu
Back to cohort
Record W2075666781 · doi:10.1118/1.2761410

TU‐EE‐A3‐01: Evaluating the Impact of Probe Depression On Prostate Displacement in Ultrasound‐Guided Prostate IMRT Treatment

2007· article· en· W2075666781 on OpenAlexaboutno aff
Chuxiong Ding, X Li, Yong Yang, Dwight E. Heron, M. Saiful Huq

Bibliographic record

VenueMedical Physics · 2007
Typearticle
Languageen
FieldEngineering
TopicMedical Imaging and Analysis
Canadian institutionsnot available
Fundersnot available
KeywordsUltrasoundProstateDisplacement (psychology)MedicineProstate cancerNuclear medicineRadiologyCancerInternal medicinePsychology

Abstract

fetched live from OpenAlex

Purpose: The prostate displacement under the mechanical pressure of abdominal ultrasound probe may compromise the accuracy of ultrasound‐guided prostate IMRT treatment. The purpose of this study is to investigate the impact of ultrasound probe depression on the prostate displacement by finite element method (FEM). Method and Materials: An ultrasound system (Restitu™, Resonant Medical System, Montreal, Canada) integrated with a CT‐Sim was used to acquire a full set of 3‐D ultrasound (US)‐CT images for a typical prostate cancer patient. The patient's structures, such as body, bone, bladder, and prostate, were contoured on the CT images. These structures were utilized to generate a 3D finite element model. The mechanical properties of the patient's tissues and ultrasound probe, including elastic module (E) and Poisson's ratio (v), were set as: body (E=55kPa, v=0.45), bone (E=10GPa, v=0.45), bladder (E=10kPa, v=0.45), prostate (E=100kPa, v=0.45), and probe (E=3GPa, v=0.35), respectively. The corresponding displacement of prostate centroid during ultrasound localization was calculated by a FEM software (Ansys). Results: When the depression of ultrasound probe increased from 10mm to 50mm with an increment of 10mm on the patient's abdomen at an angle of 45 degree to horizontal plane, the displacement of prostate centroid was increased from 0.5mm to 4.9mm in the inferior direction and 0.4mm to 3.6mm in the posterior direction. There was no significant left‐right displacement of the prostate. The 3D vector displacement of prostate centroid is increased from 0.6mm to 6.1mm based on FEM calculation. Conclusion: The displacement of prostate was non‐negligible when the depression of ultrasound probe was more than 20mm on the patient's abdomen. This displacement should be considered in the 3‐D US—CT image‐registration and US‐guided radiation therapy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.741
Threshold uncertainty score0.524

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.351
Teacher spread0.327 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicMedical Imaging and AnalysisFrench-language works237,207