MétaCan
Menu
Back to cohort
Record W2076698069 · doi:10.1117/12.878182

Alignment and calibration of high frequency ultrasound (HFUS) and optical coherence tomography (OCT) 1D transducers using a dual wedge-tri step phantom

2011· article· en· W2076698069 on OpenAlexafffund
Narges Afsham, Ka Yin Chan, Leo Pan, Shuo Tang, Robert Rohling

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2011
Typearticle
Languageen
FieldEngineering
TopicOptical Coherence Tomography Applications
Canadian institutionsUniversity of British Columbia
FundersBritish Columbia Innovation Council
KeywordsImaging phantomTransducerOptical coherence tomographyCalibrationWedge (geometry)OpticsAcousticsComputer scienceMaterials sciencePhysics

Abstract

fetched live from OpenAlex

This paper introduces a novel alignment and calibration method for high frequency ultrasound (HFUS) and optical coherence tomography (OCT) 1D transducers. 2D images are constructed by means of translation of the transducers using a linear motor stage. Physical alignment of the transducers is needed in order to capture images of the same crosssectional plane, and calibration is needed to determine the relative coordinates of the images, including the image skew. A dual wedge-tri step phantom is created for both alignment and calibration. This phantom includes two symmetrical wedges and three steps that provide the user with visual feedback on how well the scan plane is aligned with the midplane of the phantom. The phantom image consists of five line segments, each of which corresponds to one of the wedges or steps. The slopes and positions of the lines are extracted from the image and compared with the phantom model. The scan plane parameters are found so that the difference between the model and extracted features is minimized. The main advantage of this phantom is that only one frame is required to determine translations, orientations, and skew parameters of the scan plane with respect to the phantom. Experimental results with ocular imaging show the ability to achieve alignment based on this method and its potential for medical applications.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.004
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.219
Teacher spread0.204 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2011
Admission routes2
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIESame topicOptical Coherence Tomography ApplicationsFrench-language works237,207