Record W2076909906 · doi:10.1118/1.1998566

WE‐D‐T‐617‐06: Development of a Sealed Water Calorimeter for Clinical Electron Beams

2005· article· en· W2076909906 on OpenAlexaff
K Stewart, Norman V. Klassen, C. K. Ross, Jan Seuntjens

Bibliographic record

VenueMedical Physics · 2005
Typearticle
Languageen
FieldMedicine
TopicRadiation Therapy and Dosimetry
Canadian institutionsNational Research Council CanadaMcGill University Health Centre
Fundersnot available
KeywordsThermistorCalorimeter (particle physics)Imaging phantomMaterials scienceIonization chamberAbsorbed doseCathode rayElectronReproducibilityIrradiationNuclear physicsPhysicsOpticsChemistryIonDetector

Abstract

fetched live from OpenAlex

Purpose: The purpose of this project is to develop a water calorimeter for use in clinical electron beams to directly determine absorbed dose to water. This work presents the design of the Electron Sealed Water (ESW) calorimeter, preliminary measurements and evaluation of correction factors. Method and Materials: The calorimeter contains a 30 × 30 × 20 cm3 water phantom surrounded by a cooling system to allow for operation at 4°C. Two thermistor probes measure the temperature change inside a glass vessel filled with high‐purity nitrogen‐saturated water. Correction factors for the glass perturbation were calculated using Monte‐Carlo simulations. Corrections for thermal conduction were simulated using Femlab finite element modeling software. Resistance of the thermistor probes was measured using a lock‐in amplifier and an AC bridge circuit. Measurements were done for 6, 9, 12, 16 and 20 MeV electron beams from a Varian Clinac 21EX with a 10 × 10 cm2 applicator at 105.5 cm SSD with the thermistor probes positioned at dref. Irradiations of 667 MU were done at 1000 MU/min for an irradiation time of 40 s. Measurements were also taken with a PTW Roos ion chamber inside the calorimeter phantom. Results: The standard error on the mean temperature change for each energy was less than 0.2%. Reproducibility for measurements on separate occasions was 0.2%. When normalized to the 12 MeV measurements, values of k'R‐50 for the Roos chamber calculated from calorimeter measurements for the 9, 16 and 20 MeV beams and agreed with TG‐51 values within 0.7 %. Conclusion: Water calorimetry in electron beams has previously been regarded as unfeasible as high gradients were thought to provoke unmanageable temperature gradients. Using the ESW calorimeter, we have shown for the first time that reproducible measurements can be performed in electron beams with energies as low as 6 MeV.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.004
Threshold uncertainty score0.020

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.005
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0040.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.042
GPT teacher head0.368
Teacher spread0.326 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicRadiation Therapy and DosimetryFrench-language works237,207