MétaCan
Menu
Back to cohort
Record W2077899790 · doi:10.1197/j.aem.2007.01.004

Illumination of Bulb-on-blade Laryngoscopes in the Out-of-hospital Setting

2007· article· en· W2077899790 on OpenAlexaff
K. W. Cheung, George Kovács, J. Adam Law, Paul Brousseau, William Hill

Bibliographic record

VenueAcademic Emergency Medicine · 2007
Typearticle
Languageen
FieldMedicine
TopicAirway Management and Intubation Techniques
Canadian institutionsNova Scotia Health AuthorityAtlantic School of TheologyQueen Elizabeth II Health Sciences Centre
Fundersnot available
KeywordsLaryngoscopesMedicineBulbSurgeryLaryngoscopyIntubation

Abstract

fetched live from OpenAlex

OBJECTIVES: To determine what percentage of out-of-hospital laryngoscopes meet a predetermined minimal illumination criterion and what factors may be altered to improve illumination. METHODS: This was an observational study of the illumination of laryngoscopes currently in use by the Emergency Health Services of Nova Scotia. Each laryngoscope was measured at baseline. This illumination was compared with the illumination after replacement with new batteries, replacement with a new bulb, replacement with new batteries and a new bulb together, and attachment of a disposable blade. The percentage of laryngoscopes that met a previously defined minimal brightness criterion was determined. RESULTS: Fifty-one laryngoscopes were measured. These laryngoscopes had a mean (+/-SD) illumination of 624 (+/-297) lux at baseline. Laryngoscope illumination increased after replacement with new batteries by 168 lux (95% confidence interval [CI] = 121 to 216), replacement with a new bulb by 679 lux (95% CI = 524 to 834), replacement with new batteries and a new bulb by 937 lux (95% CI = 770 to 1,104), and attachment of a disposable blade by 2,401 lux (95% CI = 2,075 to 2,740). Fourteen percent of laryngoscopes (7/51) at baseline met the minimal illumination criterion. CONCLUSIONS: Only a small percentage of out-of-hospital laryngoscopes met the minimal illumination criterion. There was a statistically significant increase in illumination after replacement with new batteries, replacement with a new bulb, replacement with new batteries and a new bulb, or attachment of a disposable blade. Optimal changing of lightbulbs and batteries in the out-of-hospital setting will have to be more clearly defined.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.013
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.007
Threshold uncertainty score0.014

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.013
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.362
Teacher spread0.332 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueAcademic Emergency MedicineSame topicAirway Management and Intubation TechniquesFrench-language works237,207