MétaCan
Menu
Back to cohort
Record W2079020094 · doi:10.1118/1.1323985

Depth ionization curves for an unmodulated proton beam measured with different ionization chambers

2000· article· en· W2079020094 on OpenAlexaff
Paul Mobit, George A. Sandison, C. Bloch

Bibliographic record

VenueMedical Physics · 2000
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of Calgary
Fundersnot available
KeywordsIonization chamberImaging phantomIonizationDosimetryPercentage depth dose curveBragg peakMaterials scienceAbsorbed doseProtonRADIUSAtomic physicsBeam (structure)OpticsPhysicsIonRadiationNuclear medicineNuclear physics

Abstract

fetched live from OpenAlex

Differences in depth dose curves for a 78 MeV unmodulated proton beam were measured with four commercially available ionization chambers. Measurements were performed both in water and in a commercially available solid water phantom. A depth scaling factor (Cpl) was determined from the ratio of depths distal to the Bragg peak where the dose is reduced to 80% of the maximum dose in water and in the solid water phantom. This scaling factor provides good agreement between the ionization curves at all depths in water and in this solid water phantom. There is no significant difference in the value of the depth scaling factor between the ratios (R80wat/R80med) and (R50wat/R50med), or (R100wat/R100med) for 78 MeV unmodulated proton beams. The depth scaling factor for this commercially available solid water phantom is 1.023. An effective point of measurement for a cylindrical ionization chamber was found to be slightly greater than the 50% of the cavity radius proposed by the AAPM-TG25 dosimetry protocol for electron beams and amounts to 62.5% of the cavity radius of cylindrical ionization chambers. The ion collection efficiency, Pion, and the polarity correction factor, Ppol, for all the ionization chambers studied are within 1% and 0.4% of unity, respectively. Absolute doses measured with a parallel plate ionization chamber in water and in the solid water phantom show that the doses measured in the solid water phantom are 1.4% +/- 0.5% lower than in water. The dose rate dependent response of the beam line monitor chamber was also investigated. Agreement between all the chambers was within 1.5% at the dose rates studied but the results showed that all four ionization chambers are less dose rate dependent than the monitor chamber.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.911
Threshold uncertainty score0.576

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.275
Teacher spread0.261 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations17
Published2000
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207