MétaCan
Menu
Back to cohort
Record W2080006847 · doi:10.1117/12.875563

Initial experiments with flexible conductive electrodes for potential applications in cancer tissue screening

2011· article· en· W2080006847 on OpenAlexaff
Daehan Chung, Sam Seyfollahi, Ajit Khosla, Bonnie L. Gray, Ash M. Parameswaran, Ramani Ramaseshan, Kirpal Kohli

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2011
Typearticle
Languageen
FieldEngineering
TopicAdvanced Sensor and Energy Harvesting Materials
Canadian institutionsUniversity of the Fraser ValleyBC Cancer AgencySimon Fraser University
Fundersnot available
KeywordsMaterials scienceElectrodeMicroelectrodeMicroelectromechanical systemsElectrical conductorNanotechnologyConductive polymerPolymerElectrical impedanceFabricationOptoelectronicsElastomerLithographyImaging phantomBiomedical engineeringComposite materialElectrical engineeringOpticsChemistry

Abstract

fetched live from OpenAlex

We present initial results on the fabrication and testing of micropatternable conductive nanocomposite polymer (C-NCP) electrodes for tissue impedance measurements. We present these proof-of-concept results as a first step toward the realization of our goal: an improved Electrical Impedance Scanning (EIS) system, whereby tissue can be scanned for cancerous tissue and other anomalies using large arrays of highly flexible microfabricated electrodes. Previous limitations of existing EIS system are addressed by applying polymer based microelectromechanical system (MEMS) technology. In particular, we attempt to minimize mechanical skin contact issues through the use of highly compliant elastomeric polymers, and increase the spatial resolution of measurements through the development of microelectrodes that can be micropatterned into large, highly dense arrays. We accomplish these improvements through the development of C-NCP electrodes that employ silver nanoparticle fillers in an elastomer polymer base that can be easily patterned using conventional soft lithography techniques. These new electrodes are tested on conventional tissue phantoms that mimic the electrical characteristics of human tissue. We characterize the conductivity of the electrodes (average resistivity of 7x10-5 ohm-m +/- 14.3% at 60 wt-% of silver nanoparticles), and further employ the electrodes for impedance characterization via Cole-Cole plots to show that measurements employing C-NCP electrodes are comparable to those obtained with normal macroscopic metal electrodes. We also demonstrate anomaly detection using our highly flexible Ag/AgCl C-NCP electrodes on a tissue phantom.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.272
Teacher spread0.244 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIESame topicAdvanced Sensor and Energy Harvesting MaterialsFrench-language works237,207