SU‐FF‐T‐139: Dosimetric Effect of Jaws for Small MLC Fields in 6 and 15 MV Photon Beam

2005· article· en· W2080344816 on OpenAlexaff
James C. L. Chow, Melanie Seguin, Andrew Alexander

Bibliographic record

VenueMedical Physics · 2005
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsGrand River HospitalUniversity of Waterloo
Fundersnot available
KeywordsIonization chamberOpticsDosimetryBeam (structure)Percentage depth dose curveMaterials scienceScatteringField sizeDiodeDose profilePhysicsPhotonNuclear medicineIonizationOptoelectronicsMedicine

Abstract

fetched live from OpenAlex

Purpose: This study measures how the relative position of the jaws above the MLC could affect the dose characteristics of a small field. The study focused on the variations in the percentage depth dose (PDD), beam profile and output of the small field when the jaw‐ends were moved away from the leaf‐ends, that is, when the leaf leakage/transmission and jaw scattering were changed. Method and Materials: A big scanning water tank system (RFA 300, Scanditronix Medical AB) generally used in the commissioning was used to measure the beam characteristics. A photon diode (Scanditronix Medical AB, PDF‐3G) was used to measure both the PDD and beam profile for both 6 and 15 MV photon beam. To measure the output, a micro‐ionization chamber (Scanditronix Medical AB, RK8304) was used. Results: It is found that moving the jaw to different positions away from the leaf‐ends will increase the output and penumbra width for the small fields. Such increase is particularly more significant when the field size is small (0.5 × 0.5 cm2), and when the jaw‐end is at about 1 to 2 cm from the leaf‐end, when the degree of increase changes quickly. Conclusion: Measurement is important in Intensity Modulated Radiotherapy because the jaw cannot cover all the leaf‐ends in a segment of irregular field completely. This results in additional dose contributed by (1) the end surface of the jaw, (2) the leaf‐end and (3) the inter‐ and intra‐leaf leakage/transmissions during the dosimetric measurement. In addition, most of the conventional treatment planning systems ignore these effects in the dose calculation. It is suggested that similar measurements will be carried out in the IMRT commissioning to provide information to physicists in reviewing the treatment planning system's accuracy with regard to the leaf leakage/transmission and the jaw effects.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.279
Teacher spread0.272 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→