MétaCan
Menu
Back to cohort
Record W2081931983 · doi:10.1117/12.920481

Introducing sub-wavelength pixel THz camera for the understanding of close pixel-to-wavelength imaging challenges

2012· article· en· W2081931983 on OpenAlexaff
Alain Bergeron, Linda Marchese, M. Bolduc, Marc Terroux, Denis Dufour, Éric Savard, Bruno Tremblay, Hassane Oulachgar, Michel Doucet, Loïc Le Noc, C. Alain, Hubert Jerominek

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2012
Typearticle
Languageen
FieldEngineering
TopicTerahertz technology and applications
Canadian institutionsInstitut National d'Optique
Fundersnot available
KeywordsTerahertz radiationMicrobolometerPixelOpticsWavelengthDetectorImage resolutionImage sensorPhysicsDot pitchSampling (signal processing)OptoelectronicsMaterials scienceComputer scienceBolometer

Abstract

fetched live from OpenAlex

Conventional guidelines and approximations useful in macro-scale system design can become invalidated when applied to the smaller scales. An illustration of this is when camera pixel size becomes smaller than the diffraction-limited resolution of the incident light. It is sometimes believed that there is no benefit in having a pixel width smaller than the resolving limit defined by the Raleigh criterion, 1.22 λ F/#. Though this rarely occurs in today's imaging technology, terahertz (THz) imaging is one emerging area where the pixel dimensions can be made smaller than the imaging wavelength. With terahertz camera technology, we are able to achieve sub-wavelength pixel sampling pitch, and therefore capable of directly measuring if there are image quality benefits to be derived from sub-wavelength sampling. Interest in terahertz imaging is high due to potential uses in security applications because of the greater penetration depth of terahertz radiation compared to the infrared and the visible. This paper discusses the modification by INO of its infrared MEMS microbolometer detector technology toward a THz imaging platform yielding a sub-wavelength pixel THz camera. Images obtained with this camera are reviewed in this paper. Measurements were also obtained using microscanning to increase sampling resolution. Parameters such as imaging resolution and sampling are addressed. A comparison is also made with results obtained with an 8-12 μm band camera having a pixel pitch close to the diffractionlimit.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.003
Open science0.0010.001
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.234
Teacher spread0.214 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIESame topicTerahertz technology and applicationsFrench-language works237,207