MétaCan
Menu
Back to cohort
Record W2082717367 · doi:10.1118/1.1501142

Kilovision: Thermal modeling of a kilovoltage x‐ray source integrated into a medical linear accelerator

2002· article· en· W2082717367 on OpenAlexaff
Youngbin Cho, Peter R. T. Munro

Bibliographic record

VenueMedical Physics · 2002
Typearticle
Languageen
FieldMedicine
TopicRadiation Therapy and Dosimetry
Canadian institutionsWestern UniversityOttawa Regional Cancer Foundation
Fundersnot available
KeywordsLinear particle acceleratorMedical imagingNuclear medicineMedical physicsPhysicsMaterials scienceOpticsMedicineBeam (structure)Radiology

Abstract

fetched live from OpenAlex

The thermal and thermo-mechanical (fatigue) properties of a stationary-anode kilovoltage x-ray source that can be integrated into the head of a medical linear accelerator have been modeled. A finite element program has been used to model two new target designs. The first design makes minor modifications to the existing target assembly of a Varian medical linear accelerator, while the second design adds an additional cooling tube, changes the target angle, and uses a tungsten-rhenium alloy rather than tungsten as the kilovoltage target material. The thermal calculations have been used to generate cyclic stress/strain values from which estimates of fatigue in the target designs have been made. Both kilovoltage and megavoltage operation have been studied. Analysis of the megavoltage operation shows that there are only small differences in the thermal and fatigue characteristics after the target assembly is modified to include a kilovoltage target. Thus, megavoltage operation should not be compromised. The first kilovoltage target design can handle a 900 W heat load (e.g., 120 kVp, 7.5 mA, 2 x 2 mm2 source size); the heat load being limited by the temperature at the surface of the cooling tubes and mechanical fatigue at the surface of the target. The second design can handle a 1250 W heat load (e.g., 120 kVp, approximately 10.4 mA, 2 x 2 mm2 source size). Our calculations show that installation of a kilovoltage x-ray target is practical from thermal and thermo-mechanical perspectives.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.016

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0050.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.027
GPT teacher head0.286
Teacher spread0.259 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2002
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicRadiation Therapy and DosimetryFrench-language works237,207