MétaCan
Menu
Back to cohort

History of hemodialyzers' designs

2008· review· en· W2083477395 on OpenAlexvenueno aff
Zbylut J. Twardowski

Bibliographic record

VenueHemodialysis International · 2008
Typereview
Languageen
FieldMedicine
TopicDialysis and Renal Disease Management
Canadian institutionsnot available
Fundersnot available
KeywordsDialysisMedicineHemodialysisBiocompatible materialExtracorporeal circulationHeparinCellophaneIntensive care medicineSurgeryBiomedical engineeringChemistry

Abstract

fetched live from OpenAlex

Accumulation of knowledge requisite for development of hemodialysis started in antiquity and continued through Middle Ages until the 20th century. Firstly, it was determined that the kidneys produce urine containing toxic substances that accumulate in the body if the kidneys fail to function properly; secondly, it was necessary to discover the process of diffusion and dialysis; thirdly, it was necessary to develop a safe method to prevent clotting in the extracorporeal circulation; and fourthly, it was necessary to develop biocompatible dialyzing membranes. Most of the essential knowledge was acquired by the end of the 19th century. Hemodialysis as a practical means of replacing kidney function started and developed in the 20th century. The original hemodialyzers, using celloidin as a dialyzing membrane and hirudin as an anticoagulant, were used in animal experiments at the beginning of the 20th century, and then there were a few attempts in humans in the 1920s. Rapid progress started with the application of cellophane membranes and heparin as an anticoagulant in the late 1930s and 1940s. The explosion of new dialyzer designs continued in the 1950s and 1960s and ended with the development of capillary dialyzers. Cellophane was replaced by other dialyzing membranes in the 1960s, 1970s, and 1980s. Dialysis solution was originally prepared in the tank from water, electrolytes, and glucose. This solution was recirculated through the dialyzer and back to the tank. In the 1960s, a method of single-pass dialysis solution preparation and delivery system was designed. A large quantity of dialysis solution was used for a single dialysis. Sorbent systems, using a small volume of regenerated dialysis solution, were developed in the mid 1960s, and continue to be used for home hemodialysis and acute renal failure. At the end of the 20th century, a new closed system, which prepared and delivered ultrapure dialysis solution preparation, was developed. This system also had automatic reuse of lines and dialyzers and prepared the machine for the next dialysis. This was specifically designed for quotidian home hemodialysis. Another system for frequent home hemodialysis or acute renal failure was developed at the turn of the 21st century. This system used premanufactured dialysis solution, delivered to the home or dialysis unit, as is done for peritoneal dialysis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.007
Threshold uncertainty score0.024

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.003
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.002
Science and technology studies0.0010.003
Scholarly communication0.0030.004
Open science0.0020.002
Research integrity0.0030.003
Insufficient payload (model declined to judge)0.0070.004

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.075
GPT teacher head0.324
Teacher spread0.249 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations60
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueHemodialysis InternationalSame topicDialysis and Renal Disease ManagementFrench-language works237,207