KeywordsAddendumMonte Carlo methodPhysicsRange (aeronautics)Stopping powerVariance reductionLaser beam qualityIonDosimetryStatistical physicsComputational physicsAtomic physicsMathematicsMaterials scienceQuantum mechanicsNuclear medicineStatistics

Abstract

fetched live from OpenAlex

The addendum to TG‐51, which is currently under review, will provide an expanded new set of beam quality conversion factors, kQ. The calculated values of kQ in the TG‐51 protocol are based on analytic calculations which make use of various tabulated values of measured and calculated factors uch as the water to air stopping‐power ratio, Pwall, Prepl and Pcel (for details see Ch 9 of the 2009 AAPM Summer School book, Med. Phys. Publishing, Madison, WI). However, with the development of the EGSnrc Monte Carlo system (Kawrakow, Med Phys 27(2000) 499) it is possible to accurately calculate the response of ion chambers. Also computers have became faster per unit cost and clever variance reduction techniques have been implemented for doing ion chamber calculations in complex geometries (Wulff et al, Med Phys 35(2008)1328). Hence ab initio Monte Carlo calculations of kQ have become both accurate and feasible using large clusters of computers. Values of kQ have been calculated this way for a total of 33 commonly used cylindrical ion chambers (Muir and Rogers, Med Phys 37(2010)5939) and these kQ values are accurately fit as a quadratic function of the beam quality specifier, %dd(10)x. Detailed estimates of the systematic uncertainty in these calculations have been made and range between 0.6% and 1.0%, depending on the assumptions made. The largest component is the uncertainty (previously 0.5%) in the assumed constancy with beam quality of (W/e)air, which relates the energy deposited in the cavity to the charge released in the air. In a detailed comparison of the calculated kQ values to the extensive high‐quality measurements by McEwen (Med Phys 37(2010)2179), Muir et al (Med Phys 38 (2011) 4600) found the mean percentage differences between the calculations and the experiments are 0.08(0.17), 0.07(0.32) and 0.23(0.31) in 6, 10 and 25 MV beams respectively (bracketed values are rms deviations). These discrepancies are well within the stated uncertainties of the measurements (about 0.3% to 0.4%) and the calculations (about 0.3% to 0.4% ignoring W/e uncertainties and assuming correlated uncertainties in photon cross section). These and similar comparisons for plane‐parallel chambers (Muir et al, Med Phys 39(2012) 1618) can be used to set an upper limit of 0.36% on the variation of (W/e)air with beam quality between 60Co and 25 MV beams (95% confidence). More importantly, the close agreement with experiment gives confidence in the accuracy of the Monte Carlo calculated values of kQ with a 68% confidence uncertainty of between 0.4% and 0.5%.The addendum to TG‐51 recommends use of these calculated values of kQ for the 21 ion chambers which meet the requirements for a reference class ion chamber. Learning Objectives 1. To become aware of the new addendum to TG‐51 regarding reference dosimetry in photon beams. 2. Understand how ab initio calculations of the TG‐51's beam quality conversion factor, kQ, are done 3. Understand the uncertainties involved in ab initio calculations of kQ.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.008
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.106
Threshold uncertainty score0.354

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.008
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0030.002
Science and technology studies0.0010.001
Scholarly communication0.0030.004
Open science0.0030.004
Research integrity0.0020.003
Insufficient payload (model declined to judge)0.1060.080

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.029
GPT teacher head0.313
Teacher spread0.284 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicRadiation Therapy and DosimetryFrench-language works237,207