MétaCan
Menu
Back to cohort
Record W2084892644 · doi:10.1093/eurheartj/ehl478

Adjunctive antiarrhythmic drug therapy in patients with implantable cardioverter defibrillators: a systematic review

2007· review· en· W2084892644 on OpenAlexaff
Ignacio Ferreira‐González, Laura Dos, Gordon Guyatt

Bibliographic record

VenueEuropean Heart Journal · 2007
Typereview
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsMcMaster University
Fundersnot available
KeywordsMedicineAmiodaroneSotalolDofetilidePlaceboInternal medicineDefibrillationCardiologyImplantable cardioverter-defibrillatorRandomized controlled trialAntiarrhythmic agentBeta blockerAnesthesiaAtrial fibrillationHeart diseaseHeart failure

Abstract

fetched live from OpenAlex

AIMS: To assess the efficacy and safety of adjunctive antiarrhythmic drug therapy for preventing implantable cardioverter defibrillator (ICD) therapies. METHODS AND RESULTS: We conducted a systematic literature search to identify all randomized, controlled trials assessing the efficacy of adjunctive antiarrhythmic drug therapy. Trial data were reviewed and extracted independently by two investigators in an unblinded, standardized manner. Eight trials including a total of 1889 patients were analysed. There was heterogeneity in the type of antiarrhythmic used in the treatment arm (amiodarone, sotalol, azimilide, and dofetilide) as well as in the control group (five trials compared with placebo and three trials compared with beta-blocker). The main outcome, risk of shock therapy, was reduced when comparing amiodarone plus beta-blocker with beta-blocker alone (HR 0.27; 95% CI 0.14-0.52) and when comparing sotalol with placebo (HR 0.55; 95% CI 0.4-0.78). The effect was not conclusive when comparing sotalol with other beta-blocker (HR 0.61; 95% CI 0.37-1) and azimilide or dofetilide with placebo (HR 0.78; 95% CI 0.58-1.04 and HR 0.67; 95% CI 0.43-1.04, respectively). Although there were some benefits for secondary outcomes in all antiarrhythmics, the magnitude of the benefit was higher with amiodarone. CONCLUSION: Amiodarone is the most effective treatment to reduce ICD shock therapies. The benefit of other antiarrhythmics is limited to secondary outcomes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.022
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.009
Threshold uncertainty score0.030

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.022
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0090.007
Bibliometrics0.0060.007
Science and technology studies0.0000.001
Scholarly communication0.0020.002
Open science0.0020.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.048
GPT teacher head0.334
Teacher spread0.287 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations54
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueEuropean Heart JournalSame topicCardiac pacing and defibrillation studiesFrench-language works237,207