MétaCan
Menu
Back to cohort
Record W2086600784 · doi:10.1109/tmi.2014.2354352

Automatic Deformable MR-Ultrasound Registration for Image-Guided Neurosurgery

2014· article· en· W2086600784 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueIEEE Transactions on Medical Imaging · 2014
Typearticle
Languageen
FieldComputer Science
TopicMedical Image Segmentation Techniques
Canadian institutionsMcGill UniversityMontreal Neurological Institute and HospitalConcordia University
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health ResearchFonds Québécois de la Recherche sur la Nature et les Technologies
KeywordsImage registrationArtificial intelligenceComputer visionComputer scienceOutlierImage (mathematics)

Abstract

fetched live from OpenAlex

In this work, we present a novel algorithm for registration of 3-D volumetric ultrasound (US) and MR using Robust PaTch-based cOrrelation Ratio (RaPTOR). RaPTOR computes local correlation ratio (CR) values on small patches and adds the CR values to form a global cost function. It is therefore invariant to large amounts of spatial intensity inhomogeneity. We also propose a novel outlier suppression technique based on the orientations of the RaPTOR gradients. Our deformation is modeled with free-form cubic B-splines. We analytically derive the derivatives of RaPTOR with respect to the transformation, i.e., the displacement of the B-spline nodes, and optimize RaPTOR using a stochastic gradient descent approach. RaPTOR is validated on MR and tracked US images of neurosurgery. Deformable registration of the US and MR images acquired, respectively, preoperation and postresection is of significant clinical significance, but challenging due to, among others, the large amount of missing correspondences between the two images. This work is also novel in that it performs automatic registration of this challenging dataset. To validate the results, we manually locate corresponding anatomical landmarks in the US and MR images of tumor resection in brain surgery. Compared to rigid registration based on the tracking system alone, RaPTOR reduces the mean initial mTRE over 13 patients from 5.9 to 2.9 mm, and the maximum initial TRE from 17.0 to 5.9 mm. Each volumetric registration using RaPTOR takes about 30 sec on a single CPU core. An important challenge in the field of medical image analysis is the shortage of publicly available dataset, which can both facilitate the advancement of new algorithms to clinical settings and provide a benchmark for comparison. To address this problem, we will make our manually located landmarks available online.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.956
Threshold uncertainty score0.825

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.298
Teacher spread0.279 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it