MétaCan
Menu
← Back to cohort
Record W2086898934 · doi:10.1016/j.ijchv.2014.04.003

Effects of transcatheter aortic valve implantation on ascending aorta wall elastic properties: Tissue Doppler imaging and strain Doppler echocardiography study

2014· article· en· W2086898934 on OpenAlexaff
Enrico Vizzardi, Edoardo Sciatti, Ivano Bonadei, Antonio D’Aloia, Sandro Gelsomino, Roberto Lorusso, Federica Ettori, Marco Metra

Bibliographic record

VenueIJC Heart & Vessels · 2014
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsSurgical Specialties (Canada)
Fundersnot available
KeywordsCardiologyInternal medicineMedicineAscending aortaStenosisAortic valveAortaDoppler imagingDoppler echocardiographyDiastoleBlood pressure

Abstract

fetched live from OpenAlex

BACKGROUND: Aortic elastic properties are determinants of left ventricular function by means of ventriculo-arterial coupling and indicators of cardiovascular risk. Aortic valve stenosis surgical replacement temporary reduces aortic function damaging vasa vasorum, while transcatheter aortic valve implantation (TAVI) does not influence it in the short term. We studied aortic distensibility, stiffness, M-mode strain and tissue strain after 6 and 12 months from TAVI. METHODS: We enrolled 15 patients with symptomatic severe aortic stenosis who underwent CoreValve prosthesis (Medtronic, Minneapolis, MN) implantation. Everyone had blood pressure measurement and echocardiography registration before TAVI and after 6 and 12 months. RESULTS: After TAVI NYHA class (p = 0.016), peak and mean aortic valve gradients (p < 0.001 for both) improved. Aortic distensibility increased (p = 0.032 in the first 6 months, p = 0.005 in the second 6 months, and p = 0.003 from baseline to 12 months), as well as stiffness decreased (p = 0.034; 0.090; 0.001), M-mode strain and tissue strain ameliorated (p = 0.041; 0.004; 0.004; and p = 0.013; 0.002; 0.001, respectively), tissue Doppler imaging improved (S' wave: p = 0.289; 0.347; 0.018. E' wave: p = 0.018; 0.113; 0.007. A' wave: p = 0.002; 0.532; 0.001). Moreover, some left ventricular parameters improved at 6 months, such as ejection fraction (from 49 ± 16 to 57 ± 11%; p = 0.044) and diastolic interventricular septum thickness (from 14 ± 2 to 12 ± 2 mm; p = 0.010). Even systolic pulmonary artery pressure (p = 0.019) and left diastolic dysfunction grade ameliorated (p = 0.042). CONCLUSIONS: For the first time we demonstrated that aortic elastic properties improve at 6 and 12 months after TAVI, thus influencing ventriculo-arterial coupling and ameliorating left ventricular function.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.304
Teacher spread0.294 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueIJC Heart & Vessels→Same topicCardiac Valve Diseases and Treatments→French-language works237,207→