TH‐A‐214‐11: Dose to Implantable Cardiac Devices from Cone Beam CT

2011· article· en· W2087503272 on OpenAlexaff
M. Wronski, Geordi Pang

Bibliographic record

VenueMedical Physics · 2011
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsPrincess Margaret Cancer Centre
Fundersnot available
KeywordsMedicineDosimeterNuclear medicineImaging phantomCone beam computed tomographyDosimetryCumulative doseDose profileRadiologyComputed tomography

Abstract

fetched live from OpenAlex

Purpose: To quantify the cumulative dose contribution to implantable cardiac rhythm management devices (ICRMDs) from cone beam CT (CBCT) for patients undergoing radiotherapy and to investigate dose reduction strategies. Methods: An implantable pacemaker (IP) and implantable cardioverter‐defibrillator (ICD) with internal MOSFET dosimeters were used to measure the cumulative CBCT dose to the IP and ICD. Specifically, the MOSFET threshold voltage shifts resulting from standard clinical CBCT imaging protocols were recorded and compared to shifts caused by peripheral megavoltage dose associated with 6 MV IMRT treatment delivery. The dose assessments were performed on an anthropomorphic phantom with the IP or ICD placed in the left clavicular area both inside and outside of the CBCT field of view (FOV). Two dose reduction strategies were evaluated: the use of a 2 mm copper plate to shield the device during imaging and the use of partial‐angle scanning. Results: The average internal IP and ICD doses due to standard clinical CBCT imaging protocols with the device inside the FOV were in the 2.2 – 4.3 cGy and 0.8 – 1.9 cGy range, respectively, but could reach as high as 11.2 cGy per scan. Five centimeters outside the FOV, the dose can reach up to 10% of the in‐field dose in the cranio‐caudal direction and up to 70% in the medio‐ lateral direction. Copper shielding resulted in a 3‐fold reduction in total CBCT dose and a posterior 180 degree scan reduced the dose by a factor of 8 in comparison to a full 360 degree scan. Conclusions: The CBCT imaging dose to ICRMDs can be substantial and needs to be accounted for. Use of a MOSFET dosimeter during the first treatment fraction is an effective way of obtaining a reasonable upper limit of the average cumulative ICRMD dose. Partial posterior scans can greatly reduce this dose.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.274
Teacher spread0.259 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→