MétaCan
Menu
Back to cohort
Record W2087694717 · doi:10.1111/clr.12583

Accuracy and patient‐centered outcome variables in guided implant surgery: a <scp>RCT</scp> comparing immediate with delayed loading

2015· article· en· W2087694717 on OpenAlexaboutno aff
M. Vercruyssen, Catherine Cox, Ignace Naert, Reinhilde Jacobs, Wim Teughels, Marc Quirynen

Bibliographic record

VenueClinical Oral Implants Research · 2015
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
FundersVlaamse regeringFonds Wetenschappelijk Onderzoek
KeywordsMedicineMaxillaVisual analogue scaleRandomized controlled trialAnalgesicImplantPatient-centered outcomesAbsolute deviationMcGill Pain QuestionnaireSurgeryDentistryOrthodonticsAnesthesiaMathematics

Abstract

fetched live from OpenAlex

AIM: To assess the accuracy and patient-centered outcome of a novel guided surgery system for placing implants in an edentulous maxilla. MATERIAL AND METHODS: Fifteen consecutive patients with sufficient bone to place six implants in the maxilla were randomly assigned to the immediate loading (with delivery of the final prosthesis within 24 h) or the delayed loading treatment group. Accuracy was assessed by matching the planning CT with a postoperative CBCT. Patient-centered outcome measures were the Dutch version of the McGill Pain Questionnaire (MPQ-DLV), the health-related quality of life instrument (HRQOL), visual analog scales (VAS), the duration of the procedure, and the analgesic doses taken each day. RESULTS: A mean deviation was found at the entry point of 0.9 mm (range: 0.1-4.5, median 0.8) and of 1.2 mm (range: 0.2-4.9, median 1.1) at the apex, and an angular deviation of 2.7° (range: 0.0-6.6°, median 2.3) was observed. The mean vertical deviation was 0.5 mm (range: 0.0-3.2, median 0.4), and in a horizontal direction, this was 0.7 mm (range: 0.1-3.1, median 0.6). The mean deviation in mesio-distal direction was 0.5 mm (range: 0.0-2.3, median 0.4) and in bucco-lingual direction 0.5 mm ± 0.4 (range: 0.0-2.2, median 0.3). No statistical differences could be shown between treatment groups on pain response (MPQ-DLV), treatment perception (VAS), number or kind of pain killers, or for the HRQOLI instrument. CONCLUSION: The accuracy of a novel CT-based guide is comparable to the accuracy data of other systems. Within the limitations of this study, no difference could be found in patient-centered outcome variables after immediate or delayed loading.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.006
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.057
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0050.006
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.418
GPT teacher head0.504
Teacher spread0.086 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations29
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueClinical Oral Implants ResearchSame topicDental Implant Techniques and OutcomesFrench-language works237,207