MétaCan
Menu
Back to cohort
Record W2088539144 · doi:10.1080/10731190802239016

Transrenal Deployment of a Modular Stent Graft to Repair AAAs with Short Necks: Experiments in Dogs

2008· article· en· W2088539144 on OpenAlexaff
Robert Guidoin, M Peirano, Hector D. Baronè, Yvan Douville, Ze Zhang, Randolph Guzman, Hernán Bertoni, Yahye Merhi, Г. Маринов, Robert McGregor, Hongbo Zhang, Daniel Chappard, Guy Dionne, Xiaoyan Deng

Bibliographic record

VenueArtificial Cells Blood Substitutes and Biotechnology · 2008
Typearticle
Languageen
FieldMedicine
TopicAortic aneurysm repair treatments
Canadian institutionsMontreal Heart InstituteSt. Boniface HospitalUniversité Laval
Fundersnot available
KeywordsStentMedicineSurgeryFixation (population genetics)AneurysmEndovascular aneurysm repairAbdominal aortic aneurysm

Abstract

fetched live from OpenAlex

Severely angulated (> 60 degrees ) or short (< 15 mm) proximal necks remain significant anatomical limitations for endovascular stent-graft repairs for abdominal aortic aneurysms. Ensuring proper proximal fixation of the stent-graft to the host artery without the short-or long-term risks of endoleak or migration represents a particular technical challenge for these anatomical circumstances. An innovative balloon expandable stent combined with a weft-knitted prosthesis was specifically designed for these situations by modelling the stent to the neck anatomy without overdistension or potential barotrauma allowing better incorporation of the device. The Latecba stent-graft consists of a 2 parts modular design. The first one, Module A, is deployed at the transrenal level and consists of a Palmaz type stent whose first half is bare and second half is sutured to a crimped weft-knitted polyester graft whose distal end holds a constriction. The second Module B is a non-crimped weft-knitted graft attached to 2 stainless steel stents. The first stent is entirely contained in the proximal textile tube, allowing fixation to module A. The second stent, which is left uncovered over the distal third, ensures proper fixation of the stent-graft distally. Following the creation of a prosthetic aneurysm in the infrarenal aorta in 32 dogs, 29 received the Latecba stent-graft for scheduled durations of 10 days, 1 month, 3 months and 6 months. Proper deployment of the stent-grafts was achieved without difficulty. All 29 animals survived and the devices were all patent at sacrifice. No device defects or migrations were observed and the stent-grafts proved to be efficient in this setting to exclude the aneurysm. Analyses of the explanted devices (gross observations, RX, CT scan, IVUS, angioscopy) confirmed the stability of this modular stent-graft. Further on-going clinical investigations are warranted to validate this concept before this stent-graft becomes commercially available without any restriction.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.130
Threshold uncertainty score0.798

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.248
Teacher spread0.225 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueArtificial Cells Blood Substitutes and BiotechnologySame topicAortic aneurysm repair treatmentsFrench-language works237,207