MétaCan
Menu
Back to cohort
Record W2090520957 · doi:10.1118/1.1997929

SU‐FF‐T‐201: Implementation of EPID Based Quality Assurance Procedures for Radiation and Optical Fields

2005· article· en· W2090520957 on OpenAlexaff
J Smale, B Norrlinger, Monique van Prooijen, Alexandra Rink, Russell Heaton, M Islam

Bibliographic record

VenueMedical Physics · 2005
Typearticle
Languageen
FieldMedicine
TopicRadiation Dose and Imaging
Canadian institutionsUniversity of Toronto
Fundersnot available
KeywordsQuality assuranceImage-guided radiation therapyLinear particle acceleratorComputer scienceOpticsNuclear medicineMedical imagingMedical physicsPhysicsArtificial intelligenceMedicineBeam (structure)

Abstract

fetched live from OpenAlex

Purpose: Enhanced radiation and light field quality assurance (QA) procedures have been developed and implemented utilizing amorphous silicon electronic portal imaging devices (EPID). This effort was motivated by the fact that film exposure coupled with hand measurements are extremely time consuming and prone to many sources of error. Method and Materials: The EPID based QA procedure uses specially designed acrylic test templates, containing radio‐opaque led bars to register the position of the optical field. Images of these templates were acquired with the EPID on both Varian and Elekta linear accelerators. A MATLab based computer application was used to automatically assess light/radiation field congruence, radiation field sizes and optical field size and positioning. A three‐month pilot study using two Varian accelerators to assess both 6 MV and 18 MV photon energies was performed to validate the EPID QA procedure's efficacy and quantify its efficiency relative to film QA procedures. Results: The pilot study verified that the EPID QA system results are congruent with the hand measurements obtained from a detailed analysis of film QA measurements. Light/radiation congruence measurement performed using an EPID exhibited an absolute mean deviation of 0.37 ± 0.37 mm (1σ), relative to the film measurements. EPID based radiation field size assessments produced an absolute discrepancy of 0.57 ± 0.44mm (1σ), while film measurements yielded an absolute discrepancy of 0.61 ± 0.55mm (1σ), relative to measurements acquired using RIT software. EPID based measurements were found to be more efficiently performed, reducing the set‐up and analysis time by 55% compared to film. Conclusions: The enhanced EPID QA system can effectively replace film in routine quality assurance tasks for radiation and optical fields. This procedure saves Princess Margaret Hospital 4 man‐hours per week, and provides a user‐independent analysis procedure for objectively assessing routine QA results.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.004
Threshold uncertainty score0.015

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.006
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0040.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.382
Teacher spread0.358 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicRadiation Dose and ImagingFrench-language works237,207