MétaCan
Menu
← Back to cohort
Record W2090820214 · doi:10.1118/1.2761020

SU-FF-T-356: Preliminary Investigations of a Leucomalachite Green Hydrogel for Three-Dimensional Radiation Dosimetry

2007· article· en· W2090820214 on OpenAlexaff
K Jordan, Nikita Avvakumov, Jerry Battista

Bibliographic record

VenueMedical Physics · 2007
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsLondon Health Sciences Centre
Fundersnot available
KeywordsDosimeterXylenol orangeMaterials scienceDosimetryCuvetteGelatinIrradiationSelf-healing hydrogelsAttenuationRadiochemistryAnalytical Chemistry (journal)OpticsNuclear chemistryChromatographyChemistryNuclear medicine

Abstract

fetched live from OpenAlex

Purpose: To develop a radiochromic hydrogel dosimeter based on the conversion reaction of leuco-triphenyl-methane dye to coloured dye. Method and Materials: A systematic examination of surfactants revealed that Triton X-100 provided adequate solubility to keep leucomalachite green dissolved in 4% gelatin hydrogels. The gel dose response was increased by lowering the pH and by adding trichloroacetic acid. A cylindrical one litre volume sample was irradiated with a 12 MeV electron beam (Varian Clinac 2100C) to a dose of 30 Gy and scanned with a commercial optical cone beam CT scanner (Vista™, Modus Medical Devices Inc.). Results: The most radiation sensitive gel formulation contained: 4% gelatin, 6 mM Triton X-100, 15mM trichloroacetic acid and 0.1 mM leucomalachite green. A dose response of 0.005 cm−1Gy−1 was determined from irradiation of gel-filled 1 cm pathlength polymethymethacrylate cuvettes and measurement of the optical attenuation improved at a wavelength equal to 633 nm. Comparison of the central axis gel attenuation coefficients normalized at depth of maximum dose (dmax) with TG21-corrected ion chamber data, demonstrated agreement in the buildup region up to dmax. However, the gel over-responded at greater depths. Conclusion: Leuco dyes can be dissolved to provide transparent, colourless hydrogels by employing surfactants such as Triton X-100. The current gel formulation has a dose response approximately 20 times lower than the ferrous xylenol orange system. It is suggested that photochemistry arising from the UV light generated by the Triton X-100 scintillation fluorescence and the Cerenkov process are possible causes of a radiochromic artifact measured with electron beams. Conflict of Interest: Two of the authors (KJ, JB) have a licensing agreement with Modus Medical Devices Inc. concerning the commercialization of Vista™.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.284
Teacher spread0.271 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→