MétaCan
Menu
Back to cohort
Record W2091374605 · doi:10.1118/1.2031039

Sci‐PM Fri ‐ 07: The development and testing of an all‐glass vessel for absorbed dose to water

2005· article· en· W2091374605 on OpenAlexaff
C. K. Ross, Norman V. Klassen, M R McEwen

Bibliographic record

VenueMedical Physics · 2005
Typearticle
Languageen
FieldEnvironmental Science
TopicRadioactive contamination and transfer
Canadian institutionsNational Research Council Canada
Fundersnot available
KeywordsAbsorbed doseExothermic reactionEndothermic processMaterials scienceNuclear engineeringInertCalorimetryInert gasAqueous solutionDosimetryEnvironmental scienceChemistryComposite materialThermodynamicsAdsorptionNuclear medicinePhysics

Abstract

fetched live from OpenAlex

Calorimetry is widely used for establishing primary standards for absorbed dose. The advantage of using water as a calorimetric material is that it gives directly the absorbed dose to water, which is the quantity of interest for radiation therapy. Unfortunately, radiation‐induced chemical reactions in the water (sometimes with impurities) may be exothermic or endothermic, thus contributing to an unknown “heat defect”. Calculations and measurements show that there are a few aqueous systems for which the heat defect can be established with small uncertainty. In particular, the heat defect of pure water saturated with an inert gas or with hydrogen gas is expected to be zero after an accumulated dose of a few gray. The need for maintaining high purity water systems and techniques for cleaning, filling and sealing vessels contributes significantly to the complexity associated with water calorimetry. In an effort to overcome this limitation, we have developed a vessel in which only glass comes in contact with the water and which is flame‐sealed after being filled and saturated with an appropriate gas. We have measured the response of one such vessel over several years and found it to be stable and consistent with expected results. We believe these all‐glass vessels will ease the effort of maintaining water calorimeters as absorbed dose standards and may be used for direct comparisons among laboratories with similar devices.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.977
Threshold uncertainty score0.180

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.263
Teacher spread0.238 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicRadioactive contamination and transferFrench-language works237,207