MétaCan
Menu
Back to cohort
Record W2092505400 · doi:10.1021/ac802022z

Low Thermal Mass Liquid Chromatography

2009· article· en· W2092505400 on OpenAlexaff
Binghe Gu, Hernan Cortes, Jim Luong, Matthias Pursch, Patric Eckerle, Robert V. Mustacich

Bibliographic record

VenueAnalytical Chemistry · 2009
Typearticle
Languageen
FieldChemistry
TopicAnalytical Chemistry and Chromatography
Canadian institutionsDow Chemical (Canada)
FundersDow Chemical Company
KeywordsChemistryVan Deemter equationIsothermal processAnalyteAnalytical Chemistry (journal)ChromatographyElutionVolumetric flow rateSelectivityAtmospheric temperature rangeMass transferTemperature gradientTemperature controlHigh-performance liquid chromatographyThermodynamicsCatalysis

Abstract

fetched live from OpenAlex

A novel technique, low thermal mass liquid chromatography (LTMLC), is introduced in this study. The use of an LTM assembly that utilizes the principle of resistive wire heating and a temperature sensor to accurately deliver unprecedented heating (up to 1800 degrees C/min) or cooling (100 to approximately 200 degrees C/min) rates is reported. With the use of packed microcolumns (<0.5 mm i.d.), essentially instantaneous heat transfer from the assembly to the mobile phase was obtained. A systematic investigation was conducted to study the performance of the LTMLC technique. Both isocratic and gradient mobile phase conditions were used. For temperature control, isothermal, temperature-increasing, and temperature-decreasing gradients were applied. Three model mixtures, two of which containing neutral and acidic analytes and the other containing neutral, acidic, and basic analytes, were used to study the effect of temperature on elution time, resolution, column efficiency, and selectivity. It was found that the LTMLC experimental setup delivered reliable temperature control, as evidenced by linear van't Hoff plots for neutral and acidic compounds. The effect of temperature on the elution of basic analytes yielded nonlinear van't Hoff plots, explaining the dramatic selectivity changes observed for bases with changes in column temperature. Column efficiency generally increased with the increase in column temperature in the range of 25 to approximately 75 degrees C and decreased in the range of 75 to approximately 150 degrees C at a fixed column flow rate (3 microL/min), when extra column band broadening was taken into account. The increase in efficiency upon the increase in column temperature in the low temperature range was mainly due to the decreased mass transfer term resulting from increased analyte diffusivity. However, under even higher temperatures, the longitudinal diffusion dominated band broadening, explaining the decrease in column efficiency upon a further increase in column temperature. Resolution and selectivity decreased at elevated temperature for neutral and acidic compounds. For mixtures that contain bases, improved resolution was obtained by simultaneously tuning temperature and solvent programming. In addition to heating ability, LTMLC also demonstrated reliable cooling capability, allowing performance of oscillated or cycled temperature programming for fine-tuning the separation of critical band pairs for the first time. Finally, ultrafast reproducible LTMLC was also demonstrated, showing the potential of utilization of this technology for fast and ultrafast separations.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.005
Threshold uncertainty score0.017

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0020.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0020.001
Open science0.0020.001
Research integrity0.0020.003
Insufficient payload (model declined to judge)0.0050.007

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.227
Teacher spread0.220 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicAnalytical Chemistry and ChromatographyFrench-language works237,207