MétaCan
Menu
Back to cohort
Record W2092771299 · doi:10.1016/j.jasms.2003.11.012

Wall-less sample preparation of <i>μ</i>m-sized sample spots for femtomole detection limits of proteins from liquid based UV-MALDI matrices

2004· article· en· W2092771299 on OpenAlexafffund
Michael J. Bogan, George R. Agnes

Bibliographic record

VenueJournal of the American Society for Mass Spectrometry · 2004
Typearticle
Languageen
FieldChemistry
TopicMass Spectrometry Techniques and Applications
Canadian institutionsSimon Fraser University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsChemistryMass spectrometrySpotsSample preparationChromatographyAnalytical Chemistry (journal)Matrix (chemical analysis)DesorptionSample (material)Time-of-flight mass spectrometryMatrix-assisted laser desorption/ionizationIonizationIon

Abstract

fetched live from OpenAlex

Previously, we introduced wall-less sample preparation (WaSP), technology that involves the use of an electrodynamic balance (EDB) to prepare microm-sized sample spots for analysis by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). In that work we demonstrated the detection of femtomole quantities of a low molecular weight peptide and a hydrophobic ester (both <600 Da). Here we use WaSP to test the hypothesis that the use of small sample spot sizes and an instrument equipped with delayed extraction would increase the analytical utility of liquid sample spots for peptide and protein (>2500 Da) analysis by UV-MALDI-TOF-MS (Sze et al.; J. Am. Soc. Mass Spectrom. 1998, 9, 166-174). To aid the optimization of preparing microm-sized sample spots by WaSP, optical microscopy and mass spectrometry were used to investigate nonvolatile solute concentration effects on droplet fission and sample spot size, modifications of the EDB electric field to control droplet ejection, and the use of multiple droplet deposition to increase sample loading. Also described is a rapid deposition mode of operation for WaSP that allows single droplets generated at 1 Hz to be levitated briefly ( approximately 500 ms) before being ejected autonomously and deposited as a concentrated sample spot with a spatial accuracy of +/-5 microm. To test the sensitivity of the method, one hundred glycerol droplets (270 pL each, 27 nL total) each containing 32 amol lysozyme were deposited on top of each other one-at-a-time to create a single sample spot. Using a mass spectrometer equipped with delayed extraction to analyze this sample spot, we verified the hypothesis of Sze et al. by achieving detection limits three orders of magnitude below that previously observed for the detection of a protein by UV-MALDI-TOF-MS with a chemical-doped liquid matrix sample preparation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.043
Threshold uncertainty score0.870

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.002
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.287
Teacher spread0.270 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations24
Published2004
Admission routes2
Has abstractyes

Explore more

Same venueJournal of the American Society for Mass SpectrometrySame topicMass Spectrometry Techniques and ApplicationsFrench-language works237,207