MétaCan
Menu
Back to cohort
Record W2093232225 · doi:10.1080/15459624.2012.666467

Cortisol and Interleukin-6 Responses During Intermittent Exercise in Two Different Hot Environments with Equivalent WBGT

2012· article· en· W2093232225 on OpenAlexafffund
Heather E. Wright, Tom M. McLellan, Jill M. Stapleton, Stephen G. Hardcastle, Glen P. Kenny

Bibliographic record

VenueJournal of Occupational and Environmental Hygiene · 2012
Typearticle
Languageen
FieldMedicine
TopicExercise and Physiological Responses
Canadian institutionsNatural Resources CanadaMarkham Stouffville HospitalUniversity of Ottawa
FundersUniversity of Ottawa
KeywordsWet-bulb globe temperatureThermoregulationHeart rateAnimal scienceUrine specific gravityRelative humidityMedicinePerceived exertionChemistryInternal medicineRating of perceived exertionEndocrinologyHeat stressUrineBlood pressureBiologyMeteorology

Abstract

fetched live from OpenAlex

Blood marker concentrations such as cortisol (COR) and interleukin (IL)-6 are commonly used to evaluate the physiological strain associated with work in the heat. It is unclear, however, if hot environments of an equivalent thermal stress, as defined by a similar wet bulb globe temperature (WBGT), result in similar response patterns. This study examined markers of neuroendocrine (COR) and immune (IL-6) responses, as well as the cardiovascular and thermal responses, relative to changes in body heat content measured by whole-body direct calorimetry during work in two different hot environments with equivalent WBGT. Eight males performed a 2-hr heavy intermittent exercise protocol (six 15-min bouts of cycling at a constant rate of metabolic heat production (360W) interspersed by 5-min rest periods) in Hot/Dry (46°C, 10% relative humidity [RH]) and Warm/Humid (33°C, 60% RH) conditions (WBGT ∼ 29°C). Whole-body evaporative and dry heat exchange, change in body heat content (ΔH(b)), rectal temperature (T(re)), and heart rate were measured continuously. Venous blood was obtained at rest (PRE) and the end of each exercise bout for the measurement of changes in plasma volume (PV), plasma protein (an estimate of plasma water changes), COR, and IL-6. Ratings of perceived exertion and thermal sensation were measured during the last minute of each exercise bout. No differences existed for ΔH(b), heart rate, T(re),%ΔPV, plasma protein concentration, perceptual strain (thermal sensation, perceived exertion), and COR between the Hot/Dry and Warm/Humid conditions. IL-6 exhibited an interaction effect (p = 0.041), such that greater increases were observed in the Hot/Dry (Δ = 1.61 pg·mL(-1)) compared with the Warm/Humid (Δ = 0.64 pg·mL(-1)) environment. These findings indicate that work performed in two different hot environments with equivalent WBGT resulted in similar levels of thermal, cardiovascular, and perceptual strain, which support the use of the WBGT stress index. However, the greater IL-6 response in the Hot/Dry requires further research to elucidate the effects of different hot environments and work intensities.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.196
Threshold uncertainty score0.434

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.301
Teacher spread0.274 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2012
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Occupational and Environmental HygieneSame topicExercise and Physiological ResponsesFrench-language works237,207