MétaCan
Menu
← Back to cohort
Record W2093240686 · doi:10.1118/1.2965970

Sci‐Fri AM: YIS‐08: Prototype fan beam optical computed tomography scanner for three‐dimensional dose verification in radiation therapy

2008· article· en· W2093240686 on OpenAlexaff
David A. Rudko, Derek Wells, Andrew Jirasek

Bibliographic record

VenueMedical Physics · 2008
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of VictoriaBC Cancer Agency
Fundersnot available
KeywordsScannerRadiationOpticsComputed tomographyComputer scienceComputer graphics (images)Beam (structure)PhysicsComputer visionNuclear medicineMedical physicsArtificial intelligenceMedicineRadiology

Abstract

fetched live from OpenAlex

A prototype, rapid, high precision fan beam optical computed tomography (OptCT) scanner for three‐dimensional polymer gel dosimetry of complex radiotherapy protocols has been developed. The scanner employs a sixty degree fan beam of 543 nm laser light to interrogate irradiated gel samples up to 19 cm in cross‐sectional diameter. Rapid data acquisition with minimal scattered light and minimal refraction and reflection artefacts is achieved with the unique radial design of the front and back apertures of the index matching medium tank, concentric arrangement of a CNC machined collimator and five photodiode detector arrays for light detection. Characteristics of the scanner include: an SNR of optical absorbance in light field projections of up to 100:1; SNR of optical absorbance in transmission projections of up to 92:1 for phantoms with absorbances ranging from 0.1 to 1.0 and a spatial resolution of 0.25 mm. OptCT dose maps extracted from normoxic NIPAM polymer gels irradiated with (a) a rectangular 3×3 cm2 field, (b) a 4‐field wedged treatment and (c) a C‐shaped IMRT plan are examined and compared to the Eclipse TPS. For these treatments, dose resolution is examined in steep and moderate dose gradient regions using dose difference and gamma function metrics. The effect of different OptCT reconstruction parameters on ring and streaking artefacts is also demonstrated.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.023
Threshold uncertainty score0.078

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0230.003

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.283
Teacher spread0.266 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→