MétaCan
Menu
Back to cohort
Record W2093996932 · doi:10.1002/mrm.22967

The feasibility of endorectal MR elastography for prostate cancer localization

2011· article· en· W2093996932 on OpenAlexaff
Arvin Arani, Donald B. Plewes, Axel Krieger, Rajiv Chopra

Bibliographic record

VenueMagnetic Resonance in Medicine · 2011
Typearticle
Languageen
FieldMedicine
TopicUltrasound Imaging and Elastography
Canadian institutionsHealth Sciences CentreUniversity of TorontoSunnybrook Health Science Centre
Fundersnot available
KeywordsMagnetic resonance elastographyElastographyProstateMagnetic resonance imagingImaging phantomProstate cancerElectromagnetic coilStiffnessBiomedical engineeringMedicineMaterials scienceAcousticsRadiologyCancerUltrasoundPhysics

Abstract

fetched live from OpenAlex

The objectives of this study were to evaluate the feasibility of using a rigid radio-frequency receiver endorectal coil for intracavitary prostate magnetic resonance elastography (MRE) and to demonstrate the capability of this technique for generating stiffness maps over a typical prostate volume. An endorectal coil is currently used to help improve the signal-to-noise ratio of images acquired with multiparametric magnetic resonance imaging. We propose that this same coil could also serve to generate shear waves in the prostate gland during imaging, opening up the possibility of incorporating prostate stiffness characterization into multiparametric magnetic resonance imaging. Prostate cancer has been shown to change the elasticity of tissue, suggesting that stiffness imaging (elastography) may provide supplementary diagnostic information. A rigid endorectal coil was mechanically coupled to a piezoceramic actuator and used to investigate full volume (27 slices, 2-mm thick) endorectal MRE in a prostate mimicking phantom. The low-amplitude vibrations (± 8-38 μm displacements) necessary to perform endorectal MRE did not affect the signal-to noise ratio of the coil and endorectal MRE was capable of resolving 0.1 cc (0.6 cm diameter) spherical inclusion volumes. Therefore, the results of this study, in combination with current clinical practice, motivate clinical evaluation of endorectal MRE in patients.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.105
Threshold uncertainty score0.390

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.027
GPT teacher head0.294
Teacher spread0.267 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations40
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicUltrasound Imaging and ElastographyFrench-language works237,207