MétaCan
Menu
Back to cohort
Record W2094287700 · doi:10.1667/rr13821.1

The Relative Biological Effectiveness of Low-Dose Mammography Quality X Rays in the Human Breast MCF-10A Cell Line

2014· article· en· W2094287700 on OpenAlexafffund
Caitlin E. Mills, Christopher Thome, David Koff, David W. Andrews, Douglas R. Boreham

Bibliographic record

VenueRadiation Research · 2014
Typearticle
Languageen
FieldMedicine
TopicGlobal Cancer Incidence and Screening
Canadian institutionsNOSM UniversityMcMaster UniversityMcMaster University Medical Centre
FundersMcMaster University
KeywordsMammographyNuclear medicineRelative biological effectivenessMCF-7IrradiationBreast cancerPopulationGamma rayRadiationHuman breastMedicineCancerPhysicsOpticsInternal medicine

Abstract

fetched live from OpenAlex

Mammography is used to screen a large fraction of the population for breast cancer, and mammography quality X rays are speculated to be more damaging than the higher energy X rays used for other diagnostic procedures. The radiation dose delivered to breast cells as a result of these screening exposures may be a concern. The purpose of this current study was to determine the relative biological effectiveness (RBE) of low-energy mammography X rays for radiation-induced DNA double-strand breaks evaluated using a highly sensitive automated 53BP1 assay. Automation of the 53BP1 assay enabled the quantification and analysis of meaningful image-based features, including foci counting, within the cell nuclei. Nontumorigenic, human breast epithelial MCF-10A cells were irradiated in the low-dose range with approximately 3-30 mGy of 29 kVp mammography X rays or (137)Cs (662 keV) gamma rays. The induction and resolution of the 53BP1 foci did not differ significantly between exposures to (137)Cs gamma rays and 29 kVp X rays. The RBE was calculated to be 1.1 with a standard deviation of 0.2 for the initial number of radiation-induced double-strand breaks. The radiation dose from a single mammogram did not yield a significant change in the number of detectable foci. However, analysis of additional features revealed subtle differences in the distribution of 53BP1 throughout the nuclei after exposure to the different radiation qualities. A single mammogram was sufficient to alter the distribution of 53BP1 within the nuclear area, but not into discrete foci, while a dose-matched gamma exposure was not sufficient to alter the distribution of 53BP1. Our results indicate that exposure to clinically relevant doses of low-energy mammography quality X rays does not induce more DNA double-strand breaks than exposure to higher energy photons.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.014
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.086
Threshold uncertainty score0.483

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0140.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.181
GPT teacher head0.476
Teacher spread0.296 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2014
Admission routes2
Has abstractyes

Explore more

Same venueRadiation ResearchSame topicGlobal Cancer Incidence and ScreeningFrench-language works237,207