MétaCan
Menu
Back to cohort
Record W2094522291 · doi:10.1017/s1431927612013505

Hyperspectral Cathodoluminescence Imaging and Analysis Extending from Ultraviolet to Near Infrared

2012· article· en· W2094522291 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

aboutThe title or abstract carries a Canadian signal from the geographic lexicon.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueMicroscopy and Microanalysis · 2012
Typearticle
Languageen
FieldPhysics and Astronomy
TopicGaN-based semiconductor devices and materials
Canadian institutionsnot available
Fundersnot available
KeywordsHyperspectral imagingCathodoluminescenceInfraredUltravioletChemical imagingRemote sensingMaterials scienceOpticsGeologyPhysicsOptoelectronics

Abstract

fetched live from OpenAlex

The measurement of near-infrared (NIR) cathodoluminescence (CL) with sufficient sensitivity to allow full spectral mapping has been investigated through the application of optimized grating spectrometers that allow the ultraviolet (UV), visible, and NIR CL spectra to be measured simultaneously. Two optical spectrometers have been integrated into an electron microprobe, allowing simultaneous collection of hyperspectral CL (UV-NIR), characteristic X-rays, and electron signals. Combined hyperspectral CL spectra collected from two natural apatite (Ca5[PO4]3[OH,F]) samples from Wilberforce (Ontario, Canada) and Durango (Mexico) were qualitatively analyzed to identify the emission centers and then deconvoluted pixel-by-pixel using least-squares fitting to produce a series of ion-resolved CL intensity maps. Preliminary investigation of apatite has shown strong NIR emissions associated primarily with the rare-earth element Nd. Details of growth and alteration were revealed in the NIR that were not discernable with electron-induced X-ray mapping. Intense emission centers from Nd3+ and Sm3+ were observed in the spectra from both apatites, along with minor emissions from other 3+ rare-earth elements. Quantitative electron probe microanalysis was performed on points within the mapped area of the Durango apatite to produce a calibration line relating cathodoluminescent intensity of the fitted peak centered at 1,073 nm (1.156 eV) to the Nd concentration.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.195
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.271
Teacher spread0.259 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it