MétaCan
Menu
Back to cohort
Record W2094873540 · doi:10.1118/1.2962645

TU‐FF‐A2‐02: Dual‐Fields Rotational Total Skin Electron Irradiation/therapy

2008· article· en· W2094873540 on OpenAlexaboutno aff
Meng Xu, Anil Sethi, GP Glasgow, Mingcheng Gao, Yuhe Ke, I Rusu, John C. Roeske, Alexander Chi, Richard Garza

Bibliographic record

VenueMedical Physics · 2008
Typearticle
Languageen
FieldMedicine
TopicNonmelanoma Skin Cancer Studies
Canadian institutionsnot available
Fundersnot available
KeywordsImaging phantomDosimetryIonization chamberNuclear medicineMaterials scienceLinear particle acceleratorDose profileIrradiationField sizeBeam (structure)Biomedical engineeringOpticsPhysicsMedicineIonizationNuclear physics

Abstract

fetched live from OpenAlex

Purpose: We have developed a new technique for rotational total skin electron therapy (RTSET). The technique combines the rotational method of McGill University with the Stanford University angled dual‐fields method. We report dosimetry characteristics and in‐vivo dosimetry. Method and Materials: Patients stand on a rotational (0.9 rpm) platform at an extended SSD (332cm) with field‐size 133‐cm by 133‐cm. The gantry is angled 70° and 110° so that beam points above patient's head and below patient's feet, respectively, in order to minimize contaminant x‐ray dose. A “high‐dose‐rate” mode (600 MU/min) on a Varian‐21EX delivers a 6 MeV‐electron beam. Daily treatments require only about 0.5 h, one‐half of which is used for patient set‐up. Shields are used for eyes, nails, and toes. Dosimetry measurements include static dose‐rate at extended SSD, rotational dose‐rate for a rotating patient/phantom, and a power law correction for SSD variation. In‐vivo dose measurements are performed using XV‐films and MOSFET. Films strips are attached firmly on patient's skin to avoid any air gaps. Results: We obtained MU = Dose/(0.0751*0.39 *(332/SSD) 2.25 ). Therefore, a prescription dose of 125cGy at 325cm SSD required 4068 MU or 7.5 revolutions. The dose distribution along the vertical direction was measured by a parallel‐plate ionization chamber in a phantom. For a patient prescribed 116cGy daily, the average measured surface dose with film was 110cGy, within 5% of prescribed dose. In‐vivo MOSFET on a patient prescribed 125cGy daily, measured doses were distributed from 99% to 102% from the prescribed dose of 125cGy. Conclusion: The dual‐field RTSET offers combined advantages of shorter beam‐on time, uniform dose distribution, larger treatment fields, and less x‐ray contamination than other techniques. Our in‐vivo measurements revealed that delivered dose matched prescribed dose to < 5% and dose uniformity was within 6% variation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.734
Threshold uncertainty score0.681

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.283
Teacher spread0.266 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicNonmelanoma Skin Cancer StudiesFrench-language works237,207