MétaCan
Menu
Back to cohort
Record W2095481038 · doi:10.1161/strokeaha.114.005211

Clinical Correlates of Infarct Shape and Volume in Lacunar Strokes

2014· article· en· W2095481038 on OpenAlexaff
Negar Asdaghi, Lesly A. Pearce, Makoto Nakajima, Thalia S. Field, Carlos Bazan, Franco Cermeno, Leslie A. McClure, David C. Anderson, Robert G. Hart, Oscar Benavente

Bibliographic record

VenueStroke · 2014
Typearticle
Languageen
FieldMedicine
TopicAcute Ischemic Stroke Management
Canadian institutionsMcMaster UniversityUniversity of British Columbia
FundersNational Center for Advancing Translational SciencesNational Institute of Neurological Disorders and StrokeNational Institute of Diabetes and Digestive and Kidney Diseases
KeywordsMedicineStroke (engine)Lacunar strokeCardiologyInternal medicineRisk factorInfarctionLacunar infarctionStroke recoveryCerebral infarctionIschemiaIschemic strokeMyocardial infarction

Abstract

fetched live from OpenAlex

BACKGROUND AND PURPOSE: Infarct size and location are thought to correlate with different mechanisms of lacunar infarcts. We examined the relationship between the size and shape of lacunar infarcts and vascular risk factors and outcomes. METHODS: We studied 1679 participants in the Secondary Prevention of Small Subcortical Stroke trial with a lacunar infarct visualized on diffusion-weighted imaging. Infarct volume was measured planimetrically, and shape was classified based on visual analysis after 3-dimensional reconstruction of axial MRI slices. RESULTS: Infarct shape was ovoid/spheroid in 63%, slab in 12%, stick in 7%, and multicomponent in 17%. Median infarct volume was smallest in ovoid/spheroid relative to other shapes: 0.46, 0.65, 0.54, and 0.90 mL, respectively (P<0.001). Distributions of vascular risk factors were similar across the 4 groups except that patients in the ovoid/spheroid and stick groups were more often diabetic and those with multicomponent had significantly higher blood pressure at study entry. Intracranial stenosis did not differ among groups (P=0.2). Infarct volume was not associated with vascular risk factors. Increased volume was associated with worse functional status at baseline and 3 months. Overall, 162 recurrent strokes occurred during an average of 3.4 years of follow-up with no difference in recurrent ischemic stroke rate by shape or volume. CONCLUSIONS: In patients with recent lacunar stroke, vascular risk factor profile was similar among the different infarct shapes and sizes. Infarct size correlated with worse short-term functional outcome. Neither shape nor volume was predictive of stroke recurrence. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00059306.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.005
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.292
Teacher spread0.276 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations37
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueStrokeSame topicAcute Ischemic Stroke ManagementFrench-language works237,207