MétaCan
Menu
Back to cohort

<b>Initial Experience with a Low Profile, High Energy Excimer Laser Catheter for Heavily Calcified Coronary Lesion Debulking:</b> Parameters and Results of First Seven Human Case Experiences

2001· article· en· W2096363894 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
aboutThe title or abstract carries a Canadian signal from the geographic lexicon.

Bibliographic record

VenueJournal of Interventional Cardiology · 2001
Typearticle
Languageen
FieldMedicine
TopicCoronary Interventions and Diagnostics
Canadian institutionsVictoria Heart Institute Foundation
Fundersnot available
KeywordsMedicineTIMIAngioplastyCatheterDebulkingAnginaMyocardial infarctionStentBalloonThrombolysisSurgeryUnstable anginaRadiologyRestenosisCardiologyInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Excimer laser coronary angioplasty (ELCA) has not been used in the setting of highly calcified, tight stenoses because the energies required to use existing catheters would lead to excessive heat damage and dissection. There are, however, cases that frequently benefit from debulking prior to percutaneous intervention. A new, small laser catheter capable of high energies and repetition was previously examined in vitro. This study describes the first in vivo use. PURPOSE: To determine the safety and feasibility of a new, low profile, high energy laser catheter for creating a pilot hole to facilitate coronary angioplasty and stenting in patients with heavily calcified and occluded coronary arteries where a balloon has either failed to pass or was predicted to perform poorly. These patients represent the first patients treated with this new catheter. METHODS: At a high volume center, seven consecutive patients with anatomy as summarized above were treated and studied with QCA and then followed for 30 days postprocedure for complications and Canadian Cardiovascular Society (CCS) angina class. RESULTS: The laser catheter crossed five out of seven lesions and partially penetrated the remaining lesions. The mean maximum luminal diameter (MLD) postlasing was 1.0 mm with Thrombolysis in Myocardial Infarction (TIMI) 3 flow. It was possible to easily balloon and stent after the pilot hole creation in all but one patient. TIMI 3 was achieved for the final result after adjunct therapy in all patients. All patients except one, who died at 3 months postprocedure of stroke, were improved by an average of two angina classes. No late procedural-related complications developed. CONCLUSIONS: The new, low profile laser catheter is easy to use and achieved good results in cases where a balloon either failed to pass or was predicted to give poor results. Further trials are warranted for this niche technology.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Case report · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.458
Threshold uncertainty score0.529

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.044
GPT teacher head0.336
Teacher spread0.292 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it