Three dimensional MRI study: Safety of short versus long needle peribulbar anesthesia
Bibliographic record
Abstract
BACKGROUND: The standard technique of Peribulbar block is to use 25 g 25 mm needle at the junction between the lateral one third and medial two third of the lower orbital rim in the infero-temporal quadrant of the orbit. Theoretically, insertion of longer needles increases the potential of injury to important structure; however, safety of the shorter needle had never been demonstrated. This study describes the anatomy of the orbital structures with magnetic resonance imaging (MRI) using the three-dimensional constructive interference in steady state (3D CISS) sequence to present a morphological basis for needle entry at 12.5 and 25 mm lengths. Statistical comparisons were performed at the 12.5 versus 25 mm depths. Statistical significance was indicated by P < 0.05. METHOD: Fifty patients free of orbital pathology with normal axial length were selected for MRI with the 3D CISS sequence. Original axial and multiplanar image reconstruction (MPR) images were selected for image interpretation. Orbital structures were identified at 12.5 and 25 mm depths from the orbital rim to compare significant differences in anatomy between the two imaging planes at the expected needle depth and to assess the size of the globe and the orbit. RESULTS: The cross sectional area of the extraocular muscles were statistically significantly smaller at the 12.5 mm plane (P = 0.001). The area of inferotemporal fat was statistically significantly larger at the 12.5 mm plane (P = 0.033). There was no statistical difference in the inferonasal and superonasal fat areas at different depths (P = 0.34, P = 0.35 respectively). The size of the orbit and globe was significantly larger at 12.5 mm (P = 0.001). There was no difference between depths in the presence or absence of neurovascular bundles and supporting structures including the intramuscular septae. CONCLUSION: There is a larger structure-free space at a depth of 12.5 mm than at 25 mm. Therefore, the inference is that a needle inserted in the infero-temporal zone to a depth of 12.5 mm is less likely to injure the eyeball or extra-ocular muscles than one advanced to 25 mm.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".