MétaCan
Menu
Back to cohort

Hemodialysis vascular access monitoring: Current concepts

2009· review· en· W2097829425 on OpenAlexvenueno aff
Michael Allon, Michelle L. Robbin

Bibliographic record

VenueHemodialysis International · 2009
Typereview
Languageen
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsnot available
FundersNational Institute of Diabetes and Digestive and Kidney Diseases
KeywordsMedicineStenosisThrombosisAngioplastyHemodialysisSurgeryDialysisRadiologyCardiology

Abstract

fetched live from OpenAlex

Most arteriovenous grafts fail due to irreversible thrombosis, and most clotted grafts have an underlying stenotic lesion. These observations raise the plausible hypothesis that early detection of graft stenosis with preemptive angioplasty will reduce the likelihood of graft thrombosis. A number of noninvasive methods can be used to detect hemodynamically significant graft stenosis with a high positive predictive value. These tests include clinical monitoring, as well as surveillance by static dialysis venous pressures, flow monitoring, or duplex ultrasound. However, these surveillance tests have a much lower positive predictive value for graft thrombosis in the absence of preemptive angioplasty. In other words, none of the currently available surveillance tests can reliably distinguish between stenosed grafts destined to clot, and those that will remain patent without intervention. As a consequence, any program of graft surveillance necessarily results in a substantial proportion of unnecessary angioplasties. Moreover, a substantial proportion of grafts thrombose despite a normal antecedent surveillance test. Numerous observational studies have found an impressive reduction of graft thrombosis after implementation of a stenosis surveillance program. In contrast, 5 of 6 randomized clinical trials failed to show a reduction of graft thrombosis in patients undergoing graft surveillance, as compared with those receiving only clinical monitoring. The lack of benefit of surveillance is largely attributable to the rapid recurrence of stenosis after angioplasty. Thus, routine surveillance for graft stenosis, with preemptive angioplasty, cannot be recommended for reduction of graft thrombosis. Future research should be directed at pharmacologic interventions to prevent graft stenosis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Research integrity, Insufficient payload (model declined to judge)
Consensus categoriesInsufficient payload (model declined to judge)
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.984
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0050.005
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0000.001
Open science0.0030.001
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0040.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.145
GPT teacher head0.489
Teacher spread0.344 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; both teacher heads agree on what is shown here.

Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations84
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueHemodialysis InternationalSame topicCentral Venous Catheters and HemodialysisFrench-language works237,207