MétaCan
Menu
Back to cohort
Record W2098622543 · doi:10.1148/radiol.12112263

MR Imaging–controlled Transurethral Ultrasound Therapy for Conformal Treatment of Prostate Tissue: Initial Feasibility in Humans

2012· article· en· W2098622543 on OpenAlexafffund
Rajiv Chopra, Alexandra Colquhoun, Mathieu Burtnyk, W. Apoutou N’Djin, Ilya Kobelevskiy, Aaron Boyes, Kashif Siddiqui, Harry Foster, Linda Sugar, Masoom A. Haider, Michael Bronskill, Laurence Klotz

Bibliographic record

VenueRadiology · 2012
Typearticle
Languageen
FieldMedicine
TopicProstate Cancer Diagnosis and Treatment
Canadian institutionsSunnybrook Health Science Centre
FundersCanadian Institutes of Health Research
KeywordsMedicineProstatectomyProstate cancerProstateMagnetic resonance imagingUltrasoundUrologyNuclear medicineCancerRadiologyInternal medicine

Abstract

fetched live from OpenAlex

PURPOSE: To evaluate the feasibility and safety of magnetic resonance (MR) imaging-controlled transurethral ultrasound therapy for prostate cancer in humans. MATERIALS AND METHODS: This pilot study was approved by the institutional review board and was performed in eight men (mean age, 60 years; range, 49-70 years) with localized prostate cancer (Gleason score≤7, prostate-specific antigen level #15 μg/L) immediately before radical prostatectomy. All patients provided written informed consent. This phase 0 feasibility and safety study is the first evaluation in humans. Transurethral ultrasound therapy was performed with the patient under spinal anesthesia by using a clinical 1.5-T MR unit. Patients then underwent radical prostatectomy, and the resected gland was sliced in the plane of treatment to compare the MR imaging measurements with the pattern of thermal damage. The overall procedure time and coagulation rate were measured. In addition, the spatial targeting accuracy was evaluated, as was the thermal history along the thermal damage boundaries in the gland. RESULTS: The average procedure time was 3 hours, with 2 or fewer hours spent in the MR unit. The treatment was well tolerated by all patients, and a temperature uncertainty of less than 2°C was observed in the treatments. The mean temperature and thermal dose measured along the boundary of thermal coagulation were 52.3°C±2.1 and 3457 (cumulative equivalent minutes at 43°C)±5580, respectively. The mean treatment rate was 0.5 mL/min, and a spatial targeting accuracy of -1.0 mm±2.6 was achieved. CONCLUSION: MR imaging-controlled transurethral ultrasound therapy is feasible, safe, and well tolerated. This technology could be an attractive approach for whole-gland or focal therapy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.145
Threshold uncertainty score0.569

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.039
GPT teacher head0.360
Teacher spread0.320 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations106
Published2012
Admission routes2
Has abstractyes

Explore more

Same venueRadiologySame topicProstate Cancer Diagnosis and TreatmentFrench-language works237,207