MétaCan
Menu
Back to cohort
Record W2098707360 · doi:10.1088/0031-9155/57/6/1499

Theoretical dosimetry estimations for radioisotopes produced by proton-induced reactions on natural and enriched molybdenum targets

2012· article· en· W2098707360 on OpenAlexafffund
Xinchi Hou, A. Ćeller, Joshua Grimes, François Bénard, T.J. Ruth

Bibliographic record

VenuePhysics in Medicine and Biology · 2012
Typearticle
Languageen
FieldMedicine
TopicRadiopharmaceutical Chemistry and Applications
Canadian institutionsTRIUMFBC Cancer AgencyUniversity of British Columbia
FundersNatural Resources CanadaNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health Research
KeywordsCyclotronRadiochemistryDosimetryTechnetiumProtonIsotopeMolybdenumNuclear reactionBeam (structure)PertechnetateIrradiationNuclear medicineChemistryMaterials scienceNuclear physicsPhysicsNuclear chemistryMedicineElectron

Abstract

fetched live from OpenAlex

This study presents a summary of the dosimetry calculations performed for three technetium agents most commonly used in nuclear medicine diagnostic studies, namely sestamibi™, phosphonates and pertechnetate, labeled with cyclotron-produced technetium. Calculated patient doses were compared to those that would be delivered by the same radiotracers labeled with technetium obtained from a generator produced in a reactor. The main difference is that technetium from a generator is pure, i.e. contains only (99m)Tc and its decay product (99g)Tc, while in a cyclotron a large number of other stable and radioactive isotopes are created. In our calculations only technetium radioisotopes (ground and isomeric states) were considered as they will be included in the radiotracer labeling process and will contribute to the patient dose. Other elements should be removed by chemical purification. These dose estimates are based on our theoretical calculations of the proton-induced reaction cross sections and radioisotope production yields. Thick targets of enriched (three different compositions) and natural molybdenum, and three initial beam energies (16, 19 and 24 MeV) were considered for irradiation times of 3, 6 and 12 h with a beam current of 200 µA. The doses were calculated for injection times corresponding to 0, 2, 8, 12 and 24 h after the end of beam.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.163
GPT teacher head0.450
Teacher spread0.287 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations32
Published2012
Admission routes2
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicRadiopharmaceutical Chemistry and ApplicationsFrench-language works237,207