MétaCan
Menu
Back to cohort
Record W2101533516 · doi:10.2214/ajr.05.1536

Sonographically Guided Percutaneous Liver Biopsy in Infants: A Retrospective Review

2006· review· en· W2101533516 on OpenAlexaff
João Amaral, J. Schwartz, Peter Chait, Michael Temple, Philip John, C. Smith, Glenn Taylor, Bairbre Connolly

Bibliographic record

VenueAmerican Journal of Roentgenology · 2006
Typereview
Languageen
FieldMedicine
TopicHepatocellular Carcinoma Treatment and Prognosis
Canadian institutionsHospital for Sick Children
Fundersnot available
KeywordsMedicineRadiologyPercutaneous biopsyPercutaneousBiopsyRetrospective cohort studyLiver biopsyMEDLINEGeneral surgeryMedical physicsSurgery

Abstract

fetched live from OpenAlex

OBJECTIVE: The purpose of our study was to assess the technical success and complication rate of sonographically guided percutaneous liver biopsies performed in infants under 1 year old at a tertiary pediatric center. MATERIALS AND METHODS: Retrospective analysis of 65 biopsies performed in 61 infants between January 1999 and December 2003 was conducted. Data collected included patient demographics; details of the biopsy procedure including indication, needle type and size, number of passes, and samples; pathology results; and procedure-related complications. RESULTS: The 61 infants studied included 37 males and 24 females with a mean age of 119 days (age range, 7-348 days; median age, 83 days) and a mean weight of 4.5 kg (1.9-8.3 kg). A total of 65 biopsies were performed in these 61 infants. General anesthesia was used in 66.1% of procedures. An 18-gauge needle was used in 47 (72.3%) procedures. Coaxial technique was used in seven procedures, and five biopsy tracts were embolized. In 63 of 65 procedures, the mean number of passes was 1.8. In two procedures, using a coaxial technique, 11 and 12 passes were made. One biopsy was considered technically unsuccessful, and 64 of 65 (98.5%) of the biopsies provided adequate tissue for pathologic analysis. There were three (4.6%) major complications related to bleeding: one requiring a blood transfusion, one requiring surgery, and one arteriobiliary fistula requiring transarterial embolization. Three (4.6%) minor complications also occurred. There were no deaths. CONCLUSION: Sonographically guided percutaneous liver biopsy in infants is a good and effective diagnostic tool. The complication rate, however, even when performed by an experienced physician, is not insignificant in this age group of patients.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.934
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0060.002
Bibliometrics0.0010.002
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.055
GPT teacher head0.319
Teacher spread0.263 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designOther design
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations62
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueAmerican Journal of RoentgenologySame topicHepatocellular Carcinoma Treatment and PrognosisFrench-language works237,207