MétaCan
Menu
← Back to cohort

Evaluation of the Effectiveness of a Water Lift System in the Sinus Membrane‐Lifting Operation as a Sinus Surgical Instrument

2010· article· en· W2102402690 on OpenAlexvenueno aff
Dae Young Kim, Yusaku Itoh, Tae Ho Kang

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2010
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsSinus liftSinus (botany)Lift (data mining)MedicineMaxillary sinusDentistrySurgeryBiomedical engineeringOrthodonticsComputer scienceBiologyData mining

Abstract

fetched live from OpenAlex

PURPOSE: The effectiveness of a Water Lift System in the sinus membrane-lifting operation was examined. This investigation focused on the capability of this equipment to reduce the risk of Schneiderian membrane perforation. MATERIALS AND METHODS: A preliminary clinical study on the use of the Water Lift System in sinus membrane elevation to place implants through the sinus floor was conducted. A total of 70 sinus membrane-lifting operations were performed on patients with various bone heights ranging from 1.2 to 9.9 mm (most commonly in the range of 4-6 mm) through the lateral approach (four cases) or the crestal approach (66 cases). RESULTS: In all of the cases performed using the lateral approach, sinus membrane perforation did not occur. In the 66 cases performed using the crestal approach, Schneiderian membrane tearing occurred in two cases. The membrane tearing occurred during elevation of the Schneiderian membrane but not when a hole was drilled to access the Schneiderian membrane. One case of membrane tearing resulted from previous inflammation in the maxillary sinus, and the other case of membrane tearing was caused by application of excessive hydraulic pressure. In addition, similar outcomes were obtained and no microbial infections were observed in a total of 68 successful cases. CONCLUSIONS: In this study, the Water Lift System was confirmed to effectively reduce the risk of Schneiderian membrane perforation during the sinus membrane-lifting operation. We conclude that the Water Lift System deserves to be considered as a sinus surgical instrument, which ensures safety in the sinus membrane-lifting operation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.104
GPT teacher head0.454
Teacher spread0.350 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations34
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→