MétaCan
Menu
Back to cohort
Record W2102796294 · doi:10.1002/xrs.1358

A miniature X‐ray tube approach to measuring lead in bone using L‐XRF

2011· article· en· W2102796294 on OpenAlexafffund
David Fleming, Mihai R. Gherase, Kevin Alexander

Bibliographic record

VenueX-Ray Spectrometry · 2011
Typearticle
Languageen
FieldMaterials Science
TopicRadiation Shielding Materials Analysis
Canadian institutionsMount Allison University
FundersCanadian Institutes of Health ResearchNatural Sciences and Engineering Research Council of CanadaCanada Research Chairs
KeywordsImaging phantomMaterials scienceCross section (physics)Tube (container)Lead (geology)Nuclear medicineBiomedical engineeringPhysicsMedicineComposite material

Abstract

fetched live from OpenAlex

Abstract Using a miniature X‐ray tube and silicon PiN diode detector, an approach to measuring lead (Pb) in bone phantoms was tested. The X‐ray tube was used to excite L‐line X‐ray fluorescence (L‐XRF) of lead in bone phantoms. The bone phantoms were made from plaster of Paris and dosed with varying quantities of lead. Phantoms were made in two sets with different shapes to model different bone surfaces. One set of bone phantoms was circular in cross‐section (2.5‐cm diameter), the other square in cross‐section (2.2 cm × 2.2 cm). Using an irradiation time of 180 s (real time), five trials were run for each bone phantom. Analysis was performed for both Lα and Lβ lead X‐rays. Based on these calibration trials, (3σ 0 /slope) minimum detection limits of 7.4 ± 0.3 µg Pb g −1 (circular cross‐section) and 8.6 ± 0.6 µg Pb g −1 (square cross‐section) were determined for the bare bone phantoms. To simulate a more realistic in vivo scenario with soft tissue overlying bone, further trials were performed with a resin material placed between the experimental system and the bone phantom. For the square cross‐section bone phantoms, a layer of resin with a thickness of 1.2 mm was used, and a minimum detection limit of 17 ± 3 µg Pb g −1 determined. For the circular cross‐section phantoms, a layer of resin with an average thickness of 2.7 mm was used. From these, a more realistic minimum detection limit for in vivo applications (43 ± 7 µg Pb g −1 ) was determined. Copyright © 2011 John Wiley & Sons, Ltd.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.055
GPT teacher head0.251
Teacher spread0.196 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2011
Admission routes2
Has abstractyes

Explore more

Same venueX-Ray SpectrometrySame topicRadiation Shielding Materials AnalysisFrench-language works237,207