MétaCan
Menu
Back to cohort
Record W2103478370 · doi:10.1002/rcm.6560

A miniature condensed‐phase membrane introduction mass spectrometry (CP‐MIMS) probe for direct and on‐line measurements of pharmaceuticals and contaminants in small, complex samples

2013· article· en· W2103478370 on OpenAlexafffund
Kyle D. Duncan, Megan D. Willis, Erik T. Krogh, Christopher G. Gill

Bibliographic record

VenueRapid Communications in Mass Spectrometry · 2013
Typearticle
Languageen
FieldChemistry
TopicMass Spectrometry Techniques and Applications
Canadian institutionsVancouver Island UniversityUniversity of Victoria
FundersNatural Sciences and Engineering Research Council of CanadaVancouver Island University
KeywordsChemistryAnalyteMass spectrometryChromatographyAnalytical Chemistry (journal)PolydimethylsiloxaneDetection limitSample preparationElectrosprayTriple quadrupole mass spectrometerTandem mass spectrometrySelected reaction monitoring

Abstract

fetched live from OpenAlex

RATIONALE: High-throughput, automated analytical measurements are desirable in many analytical scenarios, as are rapid sample pre-screening techniques to identify 'positive' samples for subsequent measurements using more time-consuming conventional methodologies (e.g., liquid chromatography/mass spectrometry (LC/MS)). A miniature condensed-phase membrane introduction mass spectrometry (CP-MIMS) probe for the direct and continuous, on-line measurement of pharmaceuticals and environmental contaminants in small, complex samples is presented. METHODS: A miniature polydimethylsiloxane hollow fibre membrane (PDMS-HFM) probe is coupled with an electrospray ionization (ESI) triple quadrupole mass spectrometer. Analytes are transported from the probe to the ESI source by a methanol acceptor phase. The probe can be autosampler mounted and directly inserted in small samples (≥400 μL) allowing continuous and simultaneous pptr-ppb level detection of target analytes (chlorophenols, triclosan, gemfibrozil, nonylphenol) in complex samples (artificial urine, beer, natural water, waste water, plant tissue). RESULTS: The probe has been characterized and optimized for acceptor phase flow rate, sample mixing and probe washing. Signal response times, detection limits and calibration data are given for selected ion monitoring (SIM) and tandem mass spectrometry (MS/MS) measurements of target analytes at trace levels. Comparisons with flow cell type CP-MIMS systems are given. Analyte depletion effects are evaluated for small samples (≥400 μL). On-line measurements in small volumes of complex samples, temporally resolved reaction monitoring and in situ/in vivo demonstrations are presented. CONCLUSIONS: The miniature CP-MIMS probe developed was successfully used for the direct, on-line detection of target analytes in small volumes (40 mL to 400 μL) of complex samples at pptr to low ppb levels. The probe can be readily automated as well as deployed for in situ/in vivo monitoring, including reaction monitoring, small sample measurements and direct insertion in living plant tissue.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.142
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.105
GPT teacher head0.357
Teacher spread0.252 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations23
Published2013
Admission routes2
Has abstractyes

Explore more

Same venueRapid Communications in Mass SpectrometrySame topicMass Spectrometry Techniques and ApplicationsFrench-language works237,207