MétaCan
Menu
Back to cohort
Record W2106471111 · doi:10.1002/xrs.870

Development of a K‐shell x‐ray fluorescence measurement of cadmium in bone

2005· article· en· W2106471111 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueX-Ray Spectrometry · 2005
Typearticle
Languageen
FieldMedicine
TopicRadiation Dose and Imaging
Canadian institutionsUniversity of GuelphMcMaster University
FundersNatural Sciences and Engineering Research Council of CanadaMcMaster University
KeywordsCadmiumFluorescenceX-ray fluorescenceExcited stateChemistryNuclear medicineRadiochemistryPhysicsOpticsMedicineAtomic physics

Abstract

fetched live from OpenAlex

Abstract Cadmium is known to accumulate in the human body and chronic exposures have been clearly linked to adverse health effects, showing the kidney as the critical target organ. However, there is evidence of an association between extensive environmental exposure to cadmium and alterations in bone/calcium metabolism. Therefore, it is desirable to be able to measure bone cadmium non‐invasively in humans. Tibia was selected as a measurement site and source‐excited K‐shell x‐ray fluorescence was investigated both experimentally and computationally. Initially the 88 keV γ‐rays from 109 Cd were used to assess minimum detectable level (MDL) of cadmium in phantoms comprising plaster of Paris (bone) and wax (soft tissue). An MDL of 3–4µg g −1 was achieved for overlying tissue thicknesses of up to 5 mm. Alternative sources were 125 I and 241 Am. Monte Carlo simulation showed that the spectral contrast for 125 I would be poor. The 60 keV γ‐rays from 241 Am were more promising, provided that the 26 keV γ‐rays were filtered out. Experiments with 241 Am confirmed that a lower MDL could be achieved. However, the product of MDL and square root of dose (a figure of merit) was not improved. Since effective doses for these source‐excited x‐ray fluorescence procedures are low (typically of the order of 0.1 µSv or less), it may be that lower MDL would be preferred over lower dose. Nevertheless, development continues as a further reduction in MDL is highly desirable. Copyright © 2005 John Wiley & Sons, Ltd.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.266
Threshold uncertainty score0.443

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.262
Teacher spread0.241 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it