Abstract

fetched live from OpenAlex

Purpose: To develop a low cost, safe, intuitive, and reusable post-operative lower leg support that can be delivered rapidly and usable for several months with minimal maintenance. Methods: The lower leg support consists of a removable contoured pad secured to a support surface. This surface is attached to a double ball and socket arm which allows six degrees of freedom of movement. The double ball and socket joint is attached to the client’s wheelchair using a “U-bolt” type clamp. Results: The lower leg supports have been used clinically 14 times since September 2008. Financial records indicate the construction costs of each lower leg support are approximately $150 CDN ($90 parts, $60 Labour) which is below the $300 CDN limit for post-operative seating modifications in BC. Re-using these supports for other clients only increases their cost effectiveness. The intuitive operation of the lower leg supports enables quick and easy adjustment of the individual leg supports. Caregivers and community clinicians have used the leg supports during convalescence then returned them to be re-used. Conclusions: The functional longevity, easy installation, low cost and intuitive operation makes these leg supports suitable for post-operative lower leg positioning.Implications for RehabilitationRapid delivery of safe custom lower leg supports on the client’s own mobility aid reduces client and caregiver anxiety, meets the demands of rapid post-operative therapy and enables quick discharges when medically stable.Recycling and low construction and maintenance costs of these reusable lower leg support pads increases cost effectiveness.Adaptable mounting and positioning options reduces the need to maintain stock of mobility aids and seating systems.Intuitive operation reduces need for specialized clinician and caregiver training.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.007
Threshold uncertainty score0.024

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0070.003

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.305
Teacher spread0.296 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueDisability and Rehabilitation Assistive TechnologySame topicSurgical Sutures and AdhesivesFrench-language works237,207