Estimation of heparin leak into the systemic circulation after central venous catheter heparin lock

2005· article· en· W2109344474 on OpenAlexafffund
Mohsen Agharazii, Isabelle Plamondon, Marcel Lebel, Pierre Douville, Simon Desmeules

Bibliographic record

VenueNephrology Dialysis Transplantation · 2005
Typearticle
Languageen
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsUniversité LavalHôtel-Dieu de Québec
FundersCanadian Institutes of Health Research
KeywordsMedicineHeparinCatheterLeakCentral venous catheterVascular accessActivated clotting timeSurgeryLock (firearm)AnesthesiaHemodialysis

Abstract

fetched live from OpenAlex

BACKGROUND: Although most catheter problems in haemodialysis are related to infection or clotting, bleeding associated with the heparin lock is of clinical importance especially during peri-operative conditions. The objective of this in vitro study is to estimate the volume of heparin that may leak into the circulation immediately after performing a catheter lock. METHODS: Different volumes (ml) of a dextrose solution were used to perform a catheter lock on haemodialysis catheters. The tip of the catheter was placed in a test tube containing water for a pre-specified period. The final concentrations of dextrose in the test tube were used to determine the volume of solution that leaked from the catheter. RESULTS: When the total lumen volume was filled, the catheter leak was estimated to be 0.59+/-0.03 and 0.71+/-0.04 ml after 15 and 25 s, respectively. There was a continuous leak of 1.23+/-0.41, 2.20+/-0.34 and 3.38+/-0.23 ml at 5, 15 and 30 min, respectively, after performing a catheter lock on a catheter with a total lumen volume of 4.5 ml. The catheter leak was significantly reduced when only 3.7 ml of solution was used to fill the total lumen volume of 4.5 ml. CONCLUSION: The present study demonstrates a significant early and late leakage from the catheter that occurs after performing a catheter lock. When applied to heparin, the volume of the unwanted catheter leak may result in adverse clinical events, especially following haemodialysis sessions and during peri-operative periods. However, these results are hypothesis-generating, and clinical studies are necessary to evaluate the efficacy of underfilling.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.293
Teacher spread0.279 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations73
Published2005
Admission routes2
Has abstractyes

Explore more

Same venueNephrology Dialysis TransplantationSame topicCentral Venous Catheters and HemodialysisFrench-language works237,207