MétaCan
Menu
Back to cohort
Record W2109482328 · doi:10.1186/s12936-015-0559-9

Evaluation of non-instrumented nucleic acid amplification by loop-mediated isothermal amplification (NINA-LAMP) for the diagnosis of malaria in Northwest Ethiopia

2015· article· en· W2109482328 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueMalaria Journal · 2015
Typearticle
Languageen
FieldMedicine
TopicMalaria Research and Control
Canadian institutionsUniversity of Calgary
FundersNational Institutes of HealthUniversity of Gondar
KeywordsLoop-mediated isothermal amplificationMalariaNested polymerase chain reactionDiagnosis of malariaPlasmodium falciparumGold standard (test)Rapid diagnostic testMedicineVirologyTropical medicinePolymerase chain reactionBiologyInternal medicineImmunologyPathologyGenetics

Abstract

fetched live from OpenAlex

BACKGROUND: Malaria is a major public health problem in sub-Saharan African countries including Ethiopia. Early and accurate diagnosis followed by prompt and effective treatment is among the various tools available for prevention, control and elimination of malaria. This study aimed to evaluate the performance of non-instrumented nucleic acid amplification loop-mediated isothermal amplification (NINA-LAMP) compared to standard thick and thin film microscopy and nested PCR as gold standard for the sensitive diagnosis of malaria in Northwest Ethiopia. METHODS: A cross-sectional study was conducted in North Gondar, Ethiopia from March to July 2014. Eighty-two blood samples were collected from malaria suspected patients visiting Kola Diba Health Centre and analysed for Plasmodium parasites by microscopy, NINA-LAMP and nested PCR. The NINA-LAMP method was performed using the Loopamp Malaria Pan/Pf detection kits for detecting DNA of the genus Plasmodium and more specifically Plasmodium falciparum using an electricity-free heater. Diagnostic accuracy outcome measures (analytical sensitivity, specificity, predictive values, and Kappa scores) of NINA-LAMP and microscopy were compared to nested PCR. RESULTS: A total of 82 samples were tested in the primary analysis. Using nested PCR as reference, the sensitivity and specificity of the primary NINA-LAMP assay were 96.8% (95% confidence interval (CI), 83.2% - 99.5%) and 84.3% (95% CI, 71.4% - 92.9%), respectively for detection of Plasmodium genus, and 100% (95% CI, 75.1% - 100%) and 81.2% (95% CI, 69.9% - 89.6%), respectively for detection of P. falciparum parasite. Microscopy demonstrated sensitivity and specificity of 93.6% (95% CI, 78.5% - 99.0%) and 98.0% (95% CI, 89.5% - 99.7%), respectively for the detection of Plasmodium parasites. Post-hoc repeat NINA-LAMP analysis showed improvement in diagnostic accuracy, which was comparable to nested PCR performance and superior to microscopy for detection at both the Plasmodium genus level and P. falciparum parasites. CONCLUSION: NINA-LAMP is highly sensitive for the diagnosis of malaria and detection of Plasmodium parasite infection at both the genus and species level when compared to nested PCR. NINA-LAMP is more sensitive than microscopy for the detection of P. falciparum and differentiation from non-falciparum species and may be a critical diagnostic modality in efforts to eradicate malaria from areas of low endemicity.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.007
metaresearch head score (Gemma)0.003
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.403
Threshold uncertainty score0.600

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0070.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.053
GPT teacher head0.330
Teacher spread0.277 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it