MétaCan
Menu
Back to cohort
Record W2109673909 · doi:10.1345/aph.1r414

Inappropriate Medication Administration Practices in Canadian Adult ICUs: A Multicenter, Cross-Sectional Observational Study

2013· article· en· W2109673909 on OpenAlexafffundabout
Salmaan Kanji, Jason Lam, Rob Goddard, Christel Johanson, Avinder Singh, Lee Petrin, Patricia Coons, Lauralyn McIntyre, Alexis F. Turgeon

Bibliographic record

VenueAnnals of Pharmacotherapy · 2013
Typearticle
Languageen
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsUniversité LavalHôpital de l'Enfant-JésusOttawa Hospital
FundersCanadian Institutes of Health Research
KeywordsMedicineObservational studyDosingIntensive careCatheterCross-sectional studyIntravenous InfusionsVenous accessEmergency medicineMedical recordAnesthesiaIntensive care medicineInternal medicineSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: Critically ill patients often receive multiple medications via continuous intravenous infusion. Coadministration of multiple medications through the same port of a venous access device often is necessary but requires an assessment of compatibility. OBJECTIVE: To describe the frequency of inappropriate coadministration of continuously infused medications via a Y-site and the use of intravenous catheters in patients in Canadian intensive care units (ICUs) in a multicenter, cross-sectional observational study. METHODS: Data pertaining to medication compatibility via Y-site infusion (medication combinations known to be incompatible or not known to be compatible), frequency of specific medications administered via continuous infusion, and catheter use (median number, location, and types of venous catheters) were collected from medical records of 434 patients in the ICUs of 13 teaching hospitals in Canada. RESULTS: Forty-six percent of patients were receiving 2 or more medication infusions simultaneously. Forty episodes of inappropriate coadministration of these infusions were identified in 37 patients. The prevalence of inappropriate coadministration of drugs via a Y-site port in all patients was 8.5% (95% CI 5.8-11.2). The prevalence of incompatible combinations via Y-site in patients with 2 or more medication infusions was 18.7%. Twenty-five of these 37 patients could have had their drug schedules rearranged into acceptable combinations, leaving 12 patients who would have required additional intravenous access to facilitate appropriate medication infusions. Median (range) number of central and peripheral venous access devices inserted per patient were 1 (0-4) and 1 (0-5), respectively. Seventeen of 95 patients with 2 or more central venous catheters could have had their medication infusions rearranged to render 1 catheter idle. CONCLUSIONS: Inappropriate Y-site combinations of medications continuously infused in Canadian ICUs are common. Management of medication infusions could, however, have been optimized in most of these situations.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.109
Threshold uncertainty score0.220

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.005
Meta-epidemiology (narrow)0.0000.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.004
Science and technology studies0.0020.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.294
GPT teacher head0.533
Teacher spread0.239 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations33
Published2013
Admission routes3
Has abstractyes

Explore more

Same venueAnnals of PharmacotherapySame topicCentral Venous Catheters and HemodialysisFrench-language works237,207