MR Imaging–guided Breast Localization System with Medial or Lateral Access

2006· article· en· W2109879413 on OpenAlexaff
Petrina A. Causer, Cameron Piron, Roberta A. Jong, Belinda Curpen, C. Luginbuhl, Joan E. Glazier, Ellen Warner, Kimberley Hill, Joanne Muldoon, Glen A. Taylor, John W. Wong, Donald B. Plewes

Bibliographic record

VenueRadiology · 2006
Typearticle
Languageen
FieldMedicine
TopicMRI in cancer diagnosis
Canadian institutionsHealth Sciences CentreSunnybrook Health Science Centre
Fundersnot available
KeywordsMedicineMagnetic resonance imagingInstitutional review boardNuclear medicineBiopsyDuctal carcinomaLesionRadiologyStereotactic biopsyStereotaxyBreast cancerCancerSurgery

Abstract

fetched live from OpenAlex

PURPOSE: To evaluate the degree of error of the authors' magnetic resonance (MR) imaging-guided needle localization system for biopsy of suspicious lesions visualized only with MR imaging, by using both prospectively recorded and retrospectively reviewed data, including MR imaging lesion coordinates as the reference standard, and to determine whether any lesion or breast characteristics affect this error. MATERIALS AND METHODS: Institutional review board approval, along with informed consent, was obtained as directed by the board. In 31 patients (age range, 34-64 years; mean age, 54.5 years), 38 wires were placed for 35 lesions by means of an MR-guided needle localization system with medial or lateral access and computer software assistance for needle placement calculation. Needle and wire placement error measurements were calculated before and after necessary placement correction, accounting for tissue shift in the z plane. The error was statistically correlated with MR imaging lesion variables, breast density, and histopathologic findings by means of univariate and multivariate linear regression analyses or two-tailed paired t test. Procedure times and the frequency of medial or lateral approaches were recorded. RESULTS: Eleven of 35 localizations (31%) were medial, and 24 of 35 (69%) were lateral. The mean total magnet time was 61.6 minutes, and the mean needle deployment time was 9 minutes (range, 4-17 minutes). Sixteen of 35 lesions (46%) were malignant (seven ductal carcinoma in situ, six invasive ductal, two invasive lobular, and one lymphoma). The mean uncorrected needle placement error was 1.3 mm (range, 0-6 mm) for the x plane, 2.4 mm (range, 0-6.5 mm) for the y plane, and 5.6 mm (range, 0-15.6 mm) for the z plane. Fourteen of 38 needles (37%) required repositioning for z-plane error. The corrected z-plane error improved to 3.2 mm (range, 0-10.0 mm). Factors that significantly increased the uncorrected error included tissue shift in the z plane (R = 0.7), small lesion size (R = -0.59), and fatty breast density (P = .029). CONCLUSION: The authors' system is accurate for performing MR-guided needle localizations for both medial and lateral approaches. Factors that increased the uncorrected needle placement error included small lesion size, fatty breast density, and tissue shift in the z plane.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.072
Threshold uncertainty score0.405

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.292
Teacher spread0.277 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations26
Published2006
Admission routes1
Has abstractyes

Explore more