MétaCan
Menu
Back to cohort
Record W2112157087 · doi:10.1186/cc11335

Effects of increasing compliance with minimal sedation on duration of mechanical ventilation: a quality improvement intervention

2012· article· en· W2112157087 on OpenAlexaff
Andre CKB Amaral, Lars Kure, Angie Jeffs

Bibliographic record

VenueCritical Care · 2012
Typearticle
Languageen
FieldMedicine
TopicSepsis Diagnosis and Treatment
Canadian institutionsHealth Sciences CentreUniversity of TorontoSunnybrook Health Science Centre
Fundersnot available
KeywordsMedicineMechanical ventilationSedationCompliance (psychology)Duration (music)Emergency medicineQuality managementIntervention (counseling)Intensive care medicineAnesthesiaNursingOperations management

Abstract

fetched live from OpenAlex

Abstract Introduction In the past two decades, healthcare adopted industrial strategies for process measurement and control. In the industry model, care is taken to avoid minimal deviations from a standard. In healthcare there is scarce data to support that a similar strategy can lead to better outcomes. Briefly, when compliance is high, further attempts to improve uptake of a process are seldom made. Our intensive care unit (ICU) improved the compliance with minimizing sedation from a high baseline of 80.4% (95% CI: 66.9 to 90.2) to 96.2% (95% CI: 95.2 to 97.0) 12 months after a quality improvement initiative. We sought to measure whether this minute improvement in compliance led to a reduction in duration of mechanical ventilation. Methods We collected data on compliance with the process during 12 months. A trained data collector abstracted data from charts every other day. Our database contains data for length of mechanical ventilation, mortality, type of admission, and acute physiology and chronic health evaluation (APACHE) II scores for the 12 months before and after the process improvement. To control for secular trends we used an interrupted-time series with adjustment for auto-correlation. We calculated the expected length of mechanical ventilation on each month by the end of the intervention period, and calculated the fitted value for the post-intervention months. Results We included 1556 patients. There was an immediate effect of the intervention (regression coefficient = -0.129, P value < 0.001) and the secular trend was a determinant of length of mechanical ventilation (regression coefficient = 0.010, P value = 0.004). The trend post-intervention was not significant (regression coefficient = 0.004, P value = 0.380). The relative change in the length of mechanical ventilation was 14.5% (IQR 13.8% to 15.8%) and the total expected decrease in mechanical ventilation days was 502.7 days (95% CI 300.9 to 729.1) over one year. Conclusions In a system already working at high levels of compliance, outcomes can still be improved. Our intervention was successful in reducing the length of mechanical ventilation. ICUs should have a process of quality assurance in place to provide constant monitoring of key quality of care processes and correct deviations from the proposed standard.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.017
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.030

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.017
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.002
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0040.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.111
GPT teacher head0.422
Teacher spread0.311 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueCritical CareSame topicSepsis Diagnosis and TreatmentFrench-language works237,207