MétaCan
Menu
← Back to cohort
Record W2117139765 · doi:10.1118/1.2241189

SU‐FF‐T‐270: Implementing a Monte Carlo Algorithm for Fields with Dynamic Beam Modifiers

2006· article· en· W2117139765 on OpenAlexaboutno aff
S. Siljamäki, L Tillikainen, H. Helminen, K. Pesola, W. Volken, Daniel Frei

Bibliographic record

VenueMedical Physics · 2006
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsnot available
Fundersnot available
KeywordsMonte Carlo methodComputationAlgorithmComputer scienceMonte Carlo algorithmVoxelMathematicsArtificial intelligenceStatistics

Abstract

fetched live from OpenAlex

Purpose: Monte Carlo methods for photons are slowly becoming available for normal clinical use. Especially for dynamic or otherwise complex fields Monte Carlo methods can be superior to traditional methods. The time to compute a Monte Carlo dose distribution up to a given accuracy is nearly independent of the complexity of the whole plan. Instead, traditional methods usually require computation time directly proportional to the complexity of the treatment. In this work, VMC++ (Voxel Monte Carlo, National Research Council, Canada) algorithm for fields with dynamic beam modifiers has been implemented. Method and Materials: A Monte Carlo implementation of an accelerator head model for dynamic fields is presented. Cases studied include dynamic wedges, sliding window IMRT fields, and complex arc fields. Except for dynamic wedges, the transport through the relevant components is modeled using VMC++. Tongue‐and‐groove, air cavities, divergent leafs, and rounded leaf tips in a multi‐leaf collimator are taken into account. In the case of dynamic wedges the jaws are modeled as impenetratable blocks. The final patient dose calculation is also done using VMC++ algorithm. Results: Results are presented for each of the dynamic components by comparing the Monte Carlo calculated data to measurements. The agreement is excellent in all cases. The calculation time varies from a few minutes to a few hours, depending on the required accuracy and target volume. Conclusion: Monte Carlo is shown to be a very competitive alternative for traditional methods in modeling accessories, especially for dynamic treatments. The results of the corresponding dose calculation match very well with measured beam data. In addition, the obtained execution times are suitable for routine clinical use. Conflict of Interest: This work has been funded by Varian Medical Systems Inc.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.006
Threshold uncertainty score0.020

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0060.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.273
Teacher spread0.268 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→