MétaCan
Menu
Back to cohort
Record W2117148148 · doi:10.1111/cid.12141

Surface Analysis of Titanium Biological Modification with Glow Discharge

2013· article· en· W2117148148 on OpenAlexvenueno aff
Yu‐Chi Chang, Sheng‐Wei Feng, Haw‐Ming Huang, Nai‐Chia Teng, Che‐Tong Lin, Hsi‐Kuei Lin, Peter‐D Wang, Wei‐Jen Chang

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2013
Typearticle
Languageen
FieldEngineering
TopicBone Tissue Engineering Materials
Canadian institutionsnot available
Fundersnot available
KeywordsFibronectinTitaniumWettingContact angleSurface roughnessAdhesionSurface finishSurface modificationMaterials scienceScanning electron microscopeChemistryChemical engineeringComposite materialBiochemistryMetallurgyCell

Abstract

fetched live from OpenAlex

BACKGROUND: Glow discharge plasma (GDP) technology has been used to graft various proteins to the titanium surface, including albumin, type I collagen, but without fibronectin. PURPOSE: The aim of this study was to evaluate and analyze the physical properties of fibronectin-grafted titanium surfaces after GDP treatment. MATERIALS AND METHODS: Grade II titanium discs after cleaning and autoclaving were considered as original specimens, thus divided into four groups. The groups were different upon two treatments (GDP only and fibronectin grafting after GDP) and two storage temperature (4°C and 25°C). The implant surface morphology was characterized by scanning electron microscopy (SEM), roughness measurement, and wettability evaluation. The concentration relationship of fibronectin was by fluorescein isothiocyanate (FITC) labeling. RESULTS: SEM images showed that regular planar texture revealed on the surface of GDP-treated group, and irregular-folding protein was found on the fibronectin-grafted discs. Fibronectin-grafted groups had higher hydrophilicity and greater surface roughness than GDP-treated specimens. The storage temperature did not make obvious difference on the surface topography, wettability, and roughness. The number of fibronectin dots on the titanium surface labeling by FITC had positive relationship with the concentration of fibronectin solution used. CONCLUSIONS: Biologically modified titanium surface is more hydrophilic and rougher than GDP-treated ones. GDP treatment combined with fibronectin grafting increased the surface hydrophilicity and surface roughness of titanium discs, which may attribute to the affinity of cell adhesion, migration, proliferation, and differentiation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.792
Threshold uncertainty score0.398

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.112
GPT teacher head0.391
Teacher spread0.279 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations24
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related ResearchSame topicBone Tissue Engineering MaterialsFrench-language works237,207