A flowmeter for unsteady liquid flow measurements in total liquid ventilation

2011· article· en· W2117570656 on OpenAlexaffabout
Anne Beaulieu, E. Foucault, P. Braud, Philippe Micheau, P. Szeger, R. Robert, Hervé Walti

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldMedicine
TopicRespiratory Support and Mechanisms
Canadian institutionsUniversité de Sherbrooke
Fundersnot available
KeywordsVenturi effectFlow measurementMechanicsMaterials scienceAcousticsDischarge coefficientLiquid oxygenParticle image velocimetryMechanical engineeringPhysicsInletNozzleEngineeringTurbulence

Abstract

fetched live from OpenAlex

A promising alternative to the use of conventional mechanical ventilators to treat pulmonary syndromes such as acute respiratory distress and meconium aspiration consists of employing total liquid ventilators, an experimental device which uses an oxygenated perfluorochemical liquid instead of a gas mixture of air and oxygen. Liquid ventilator development is an active field of research, as most components cannot be directly imported from gas ventilators and must be completely redesigned. The addressed problem is to provide a reliable measurement of the liquid flow in and out of the lungs considering that it must take into account unsteady effects to produce accurate measurements. An unsteady flowmeter was developed for implementation in the Inolivent-4, our total liquid ventilator prototype developed at Université de Sherbrooke. It consists of a symmetrical venturi tube comprising three pressure sensors and in which flow measurement is obtained by numerically solving a slightly modified version of the unsteady Bernoulli equation. A prototype was validated in-vitro by applying zero-mean sinusoidal flows. Low-frequency characterization determined the venturi discharge coefficient as a function of the Reynolds number, and higher-frequency measurements determined the applicable bandwidth of the device. The velocity profiles were measured in the venturi by particle image velocimetry (PIV), and the device was calibrated by comparison with an ultrasonic flowmeter and measurements from a piston pump. Results showed that quasi-steady flows could be accurately measured in the 5 ml/s - 60 ml/s range, while low-amplitude (≤10 ml/s) oscillatory flows were well measured for frequencies below 3 Hz. Finally, PIV experiments showed that the flat velocity profile assumption required for a simple solution of the flowmeter equation was valid within the operating range.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.015

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.005
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.129
GPT teacher head0.300
Teacher spread0.171 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2011
Admission routes2
Has abstractyes

Explore more

Same topicRespiratory Support and Mechanisms→French-language works237,207→